It is recommended to choose a molecular weight cut-off that is at least two times smaller than the molecular weight of the target molecules.
UFC5010
Filtre à centrifuger Amicon® Ultra, seuil de coupure de 10 kDa
sample volume 0.5 mL, regenerated cellulose membrane, MWCO 10 kDa
Synonyme(s) :
Concentrateur centrifuge, seuil de coupure de 10 kDa, volume d'échantillon de 0,5 ml
About This Item
Produits recommandés
Matériaux
polypropylene cap
polypropylene tube
regenerated cellulose membrane
styrene-butadiene housing
Niveau de qualité
Stérilité
non-sterile
Gamme de produits
Amicon®
Fabricant/nom de marque
Amicon® Ultra
sustainability
Greener Alternative Product
Paramètres
0.5 mL sample volume
Technique(s)
protein extraction: suitable
protein purification: suitable
Longueur
4.99 cm (1.96 in.)
Diamètre
10.8 mm
Surface de filtration
1 cm2
Volume
0.5 mL
Dimension de pores
10 kDa MWCO
Autre catégorie plus écologique
Conditions d'expédition
ambient
Description générale
Leur configuration verticale et leur surface utile de filtration en font des dispositifs très performants : traitement rapide, très bon taux de récupération (en général plus de 90 % de la solution de départ diluée) et possibilité de concentrer l'échantillon 30 ×. Leur configuration verticale permet en outre de minimiser la polarisation du soluté, et donc, le colmatage de la membrane qui en découle. Enfin, la présence d'une butée physique à l'intérieur du dispositif empêche d'atteindre la siccité et prévient les éventuelles pertes d'échantillon. Une étape de centrifugation inverse facile à mettre en œuvre permet de récupérer efficacement l'échantillon concentré (espèces retenues) après le recueil du filtrat.
Les dispositifs Amicon® Ultra de 0,5 ml sont livrés non stériles et sont à usage unique. Grâce à leur membrane verticale et à la centrifugation inverse, les filtres Amicon® Ultra de 0,5 ml offrent d'excellentes performances ainsi que des temps de centrifugation réduits.
Application
- Ultrafiltration sur membrane Ultracel® à seuil de coupure de 10 000 Da
- Concentration d'échantillons biologiques contenant des antigènes, des anticorps, des enzymes, des acides nucléiques ou des micro-organismes
- Purification des composants macromoléculaires présents dans des extraits de culture tissulaire ou des lysats cellulaires, élimination des amorces, élimination des linkers ou marqueurs macromoléculaires d'un mélange réactionnel, et élimination des protéines avant chromatographie liquide haute performance
- Dessalage, échange de tampon et dialyse des protéines
Caractéristiques et avantages
- Membrane Ultracel® en cellulose régénérée à seuil de coupure nominal de 10 kDa offrant une récupération du rétentat supérieure à 90 %
- Concentration de 500 μl en 15 μl
- Facteur de concentration de 25 × à 30 ×
- Très bonne récupération de l'échantillon (plus de 90 % de la solution de départ diluée)
- Traitement rapide : 10 à 30 minutes
- Possibilité de centrifugation inverse pour assurer l'uniformité des taux de récupération
Forme physique
Informations légales
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Articles
Commercially available protein labeling kits provide researchers with the flexibility to customize their own immunoassay detection panels.
Protein purification is simpler with Amicon Pro. The device delivers consistent sample preparation for more reliable recovery, uncompromised purity and easier data generation.
PNGase Fast denaturing buffer and enzyme provide results similar to a conventional 20-hour protocol, reducing workflow time to about 1 hour.
PNGase Fast denaturing buffer and enzyme provide results similar to a conventional 20-hour protocol, reducing workflow time to about 1 hour.
Protocoles
Best practices for standardizing and reducing the Extracellular Vesicle Preparation workflow, and eliminating contamination of EV preparations with dead-cell-derived vesicles.
Best practices for standardizing and reducing the Extracellular Vesicle Preparation workflow, and eliminating contamination of EV preparations with dead-cell-derived vesicles.
Best practices for standardizing and reducing the Extracellular Vesicle Preparation workflow, and eliminating contamination of EV preparations with dead-cell-derived vesicles.
Best practices for standardizing and reducing the Extracellular Vesicle Preparation workflow, and eliminating contamination of EV preparations with dead-cell-derived vesicles.
-
What is the tolerance for molecular weight with these spin columns? Could you reasonably purify a protein of 15 kDa using these columns, or are the tolerances too high and would result in loss of protein into the filtrate?
1 answer-
Helpful?
-
-
Is this filter suitable for purifying MHC-bound peptides as filtrate/eluate while trapping proteins and antibodies as retentate following Immunoprecipitation?
1 answer-
This product is not suitable for separating protein/peptides of different sizes.
Helpful?
-
-
If a centrifuge is unable to achieve a spinning speed of 14000 X g as recommended in the protocol, is it possible to compensate by spinning the samples for a longer duration?
1 answer-
Yes, it is possible to compensate for a lower centrifuge spinning speed by increasing the duration. This can be achieved by calculating the K factor, which determines the adjustment needed in time.
Helpful?
-
-
se puede utilizar los UFC501024 para concentrar una proteina glicosilada?
1 answer-
Yes, Amicon devices like UFC501024 can be used to concentrate any protein greater than about 20 kDa.
Helpful?
-
-
Dear Sir/Mam, can you let me know how many tubes is 8 pkg? Is it 8 tubes? Best regards, Alejandra
1 answer-
It is 8 tubes per pack.
Helpful?
-
-
What is the maximum RPM that this can be spun to ensure the membrane does not perforate?
1 answer-
The recommended G force for the Amicon® Ultra-0.5 filter is 14,000 g & 1,000 g reverse spin when using a Fixed-Angle (35 º) Rotor.
Please refer to the brochure for more information: details: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/260/181/br5002en-protein-prep-workflow-ms.pdf
Helpful?
-
Active Filters
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique