Accéder au contenu
MilliporeSigma
Toutes les photos(1)

Documents

34114

Supelco

BDE No 85 solution

50 μg/mL in isooctane, analytical standard

Synonyme(s) :

2,2′,3,4′,4-Pentabromodiphenyl ether solution, 2,2′,3,4′,4-PentaBDE, PBDE 85

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C12H5Br5O
Numéro CAS:
Poids moléculaire :
564.69
Numéro CE :
Numéro MDL:
Code UNSPSC :
41116107
ID de substance PubChem :
Nomenclature NACRES :
NA.24

Qualité

analytical standard

Durée de conservation

limited shelf life, expiry date on the label

Concentration

50 μg/mL in isooctane

Technique(s)

HPLC: suitable
gas chromatography (GC): suitable

Application(s)

environmental

Format

single component solution

Température de stockage

2-8°C

Chaîne SMILES 

Brc1ccc(Oc2ccc(Br)c(Br)c2Br)c(Br)c1

InChI

1S/C12H5Br5O/c13-6-1-3-9(8(15)5-6)18-10-4-2-7(14)11(16)12(10)17/h1-5H

Clé InChI

DMLQSUZPTTUUDP-UHFFFAOYSA-N

Description générale

BDE No 85 is an pollutant with low acute toxicity, released into the environment from various sources and belonging to the class of polybrominated diphenyl ethers. It can find wide applications as additive flame-retardants in consumer products ranging from textiles to polymers.

Application

BDE No 85 may be used as an analytical reference standard for analysis of the analyte in environmental samples such as river sediments using gas chromatography coupled to mass spectrometry (GC-MS) and selective pressurized liquid extraction followed by gas chromatography coupled to negative ion chemical ionization-mass spectrometry (GC-NCI-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Autres remarques

The customer needs to make sure that the standard is homogeneous, this can be achieved by shaking, vortexing , or sonicating the ampoule before opening the ampoule. Care should be taken when opening the ampoule to avoid any injuries from the broken glass.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

Organes cibles

Central nervous system

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

10.4 °F - closed cup

Point d'éclair (°C)

-12 °C - closed cup

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Choose from one of the most recent versions:

Certificats d'analyse (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Determination of decabromodiphenyl ether in sediments using selective pressurized liquid extraction followed by GC-NCI-MS.
Eljarrat E, et al.
Analytical and Bioanalytical Chemistry, 378(3), 610-614 (2004)
GC / MS analysis of polybrominated diphenyl ethers in fish collected from the Inland Sea of ??Seto, Japan.
Akutsu K, et al.
Chemosphere, 44(6), 1325-1333 (2001)

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique