HTS046M
ChemiSCREEN Membrane Preparation Recombinant Human ETB Endothelin Receptor
Human ETB GPCR membrane preparation for Radioligand binding Assays & GTPγS binding.
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Source biologique
human
Niveau de qualité
Produit recombinant
expressed in CHO cells
Fabricant/nom de marque
ChemiScreen
Chemicon®
Technique(s)
ligand binding assay: suitable (GTPγS)
radioligand binding assay (RLBA): suitable
Numéro d'accès NCBI
Numéro d'accès UniProt
Conditions d'expédition
dry ice
Description générale
Human ETB isoform 1
The endothelin family of peptides are potent vasoconstrictors synthesized by endothelial cells in both constitutive and inducible pathways. The biological actions of endothelins are mediated by two GPCRs, ETA and ETB (Davenport, 2002). Whereas ETA is the predominant receptor on smooth muscle cells and thus is the primary mediator of the vasoconstrictor activity, ETB is found on endothelial cells and mediates vasodilation (Nilsson et al., 1997). In addition, ETB has also been linked to renal failure, congestive heart failure, atherosclerosis, and pulmonary hypertension (D’Orléans-Juste, et al., 2002). A mutation in ETB has been found to cause Hirschsprung disease-2, a degenerative disease of the digestive tract (Puffenberger et al, 1994). Millipore’s cloned human ETB expressing cell line is made in the CHO host, which supports high levels of recombinant ETB expression on the cell surface. Thus, the ETB Membrane Preparation is an ideal tool for screening for compounds binding to ETB. The membrane preparations exhibit a Kd of 0.03-0.06 nM for [125I]-endothelin-1. With 0.2 nM [125I]-endothelin-1, 10 μg/well ETB Membrane Prep yields greater than 5 fold signal-to-background ratio.
Application
Radioligand binding assay and GTPγS binding
Actions biochimiques/physiologiques
GPCR Class: A
Protein Target: ETB
Target Sub-Family: Endothelin
Qualité
Table 1. Signal:background and specific binding values obtained in a competition binding assay with ETB membrane prep.
SPECIFICATIONS: 1 unit = 10 μg membrane preparation
Bmax: 0.49 pmol/mg
Kd: 0.03-0.06 nM
10 µg/well | |
---|---|
Signal:Background | 7.4 |
Specific Binding (cpm) | 5704 |
SPECIFICATIONS: 1 unit = 10 μg membrane preparation
Bmax: 0.49 pmol/mg
Kd: 0.03-0.06 nM
Caractéristiques
Inucbation Conditions
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C
Radioligand: [125I]Endothelin-1 (Perkin Elmer # NEX259)
Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl , 0.1% BSA, filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 5-fold signal:background with 125I-labeled Endothelin-1 at 0.25 nM.
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C
Radioligand: [125I]Endothelin-1 (Perkin Elmer # NEX259)
Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl , 0.1% BSA, filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 5-fold signal:background with 125I-labeled Endothelin-1 at 0.25 nM.
Forme physique
One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 5-fold signal:background with 125I-labeled Endothelin-1 at 0.25 nM.
Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives.
Packaging method: Membrane protein was adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80°C.
Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives.
Packaging method: Membrane protein was adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80°C.
Stockage et stabilité
Store at –70°C. Product is stable for at least 6 months from the date of receipt when stored as directed. Do not freeze and thaw.
Informations légales
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Clause de non-responsabilité
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Code de la classe de stockage
12 - Non Combustible Liquids
Classe de danger pour l'eau (WGK)
WGK 2
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique