Accéder au contenu
MilliporeSigma
Toutes les photos(2)

Documents

E511-10014

Millipore

NovaSeptum® GO Transfer Unit

sterile; β-irradiated, Tube Application; Luer; 500 mm; TPE

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41104105

Matériaux

316 stainless steel cannula
C-Flex tubing
TPE tubing
polyester body
silicone septum (platinum-cured)
silicone tubing

Niveau de qualité

Agence

according to ISO 11137 (sterilization)
according to ISO 146441
meets USP 88 Biological Reactivity (all component materials)

Stérilité

sterile; β-irradiated

Gamme de produits

NovaSeptum® GO

Caractéristiques

autoclavable: no

Paramètres

-20-50 °C temp. range (-4-122 °F)
0.50 bar max. pressure (7.25 psi)

Impuretés

<2.15 EU/device bacterial endotoxins (LAL test)

Raccords

female Luer-Lok® outlet (3-piece)
male Luer-Lok® outlet (3-piece)
outlet (injection site)

Application(s)

cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy

Température de stockage

room temp

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Device configuration: single unit, Transfer tube set
The NovaSeptum® GO Transfer Unit is intended for transfer applications. It is available with a 2 mm needle and must be used with a NovaSeptum® GO holder. Transfer units are available with a range of different tubing materials (Thermoplastic, Silicone, and C-Flex®).

Application

Non-critical
Sampling

Conditionnement

500mm TPE tube, 50 units per box

Composants

  • Septum: Platinum-cured silicone
  • Body: Polyester
  • Cannula: ASTM® 316 L Stainless steel
  • Tubing: Thermoplastic elastomer (TPE), silicone or C-Flex® tube
  • Outlet Tubing: 3-piece Luer-Lok®, containing a male, female and an injection site

Notes préparatoires

Units are integrity tested at regular intervals during manufacturing.

Aqueous extraction contains < 2.15 EU per device as determined using the Limulus Amebocyte Lysate (LAL) test.

Informations légales

ASTM is a registered trademark of American Society for Testing and Materials
C-Flex is a registered trademark of Saint-Gobain Performance Plastics Corp.
Luer-Lok is a registered trademark of Becton-Dickinson & Co.
NOVASEPTUM is a registered trademark of Merck KGaA, Darmstadt, Germany

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique