03-0201-00

Millipore

SMC® Human IgE High Sensitivity Immunoassay Kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
eCl@ss :
32161000
Nomenclature NACRES :
NA.47

Qualité

for protein analysis

Niveau de qualité

Description

analytes available: IgE

Caractéristiques

accuracy Minimum of 5 samples spiked with acceptable recovery between 86-89%.

Espèces réactives

human

Technique(s)

single molecule counting: suitable

Isotype

IgE

Description générale

The SMC Human IgE High Sensitivity Immunoassay Kit contains all reagents required to perform the assays. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format. Assay protocols are similar to existing sandwich ELISA methods with two key differences: 1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification. 2) The SMC immunoassay system detects analytes using Single Molecule Counting (SMC) technology.
The Single Molecule Counting (TM=["SMC"]) Human IgE High Sensitivity Immunoassay uses a quantitative fluorescent sandwich immunoassay technique to measure IgE in human serum and plasma samples. The user coats a capture antibody specific for human IgE onto a 96-well microplate. After blocking the plate, the user pipettes standards and samples into the coated microplate wells. During incubation, the IgE present in the sample binds to the capture antibody on the coated plate. Unbound molecules are washed away during a wash step. The fluor-labeled detection antibody is added to each well and incubated. The detection antibody recognizes and binds to IgE that has been captured onto the plate, thus completing the immunosandwich. Following the final wash step, elution buffer is added and incubated. The elution buffer dissociates the bound protein sandwich from the plate surface, releasing the labeled antibodies. These antibodies are separated during transfer to a final microplate. The reading plate is loaded onto the Erenna or TM=["SMCxPRO"] System where the labeled molecules are detected and counted. The number of fluor-labeled detection antibodies counted is directly proportional to the amount of IgE present in the sample when captured. The amount of IgE in unknown samples is interpolated from a standard curve.

Spécificité

This assay does not show cross-reactivity against immunoglobulin subclasses IgA, IgD, IdE, IgG1, IgG2, IgG3, or IgG4 from in-house testing

Composants

Assay Plate Coating Buffer Blocking Buffer Standard Diluent IgM Detection Antibody IgM Standard SMC® Human IgM Immunoassay Kit Instructions 10X Wash Buffer Buffer C Elution Buffer B Buffer 3 IgM Coating Antibody

Remarque sur l'analyse

Minimum of 5 samples spiked and diluted (at least 3 dilutions) with acceptable recovery between 86-89%

Informations légales

SMC is a registered trademark of Singulex

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pictogrammes

Skull and crossbonesHealth hazard

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Contenu apparenté

See an overview of ultrasensitive immunoassay technology with Single Molecule Counting (SMC®) technology, including its workflow, biomarker detection platform, research areas, advantages of high sensitivity SMC® assays, and more.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique