Accéder au contenu
MilliporeSigma
Toutes les photos(1)

Principaux documents

Z683086

Plas-Labs poultry isolation unit, double cubicle

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41103406
Nomenclature NACRES :
NB.35
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Entrée CA/CC

220 - 240 V AC

Fabricant/nom de marque

Plas-Labs

L × l × H

36 in. × 36 in. × 36 in., each cube

Description générale

These poultry isolation units are designed to protect, both, your fowl and the personnel from cross contamination. They are ideal for both acute and chronic studies. Because of the integrity of each compartment, multiple species can be housed in the same room if desired. All units are set up for negative pressure operation as a standard arrangement. Positive pressure set up (factory installed) is also available if preferred.
The isolation cubicles are match die-molded of "hi-tech" thermoset plastic that is autoclavable or steam sterilization. Cubicles are warm; absorb sound (quiet) and soft to the touch of various species. The problem of hypothermia is eliminated.
Watering requirements:
The isolation unit is set up to accept your house watering supply system OR, a separate water source on top of the unit. The water hoses are ½ in. inside diameter (12 mm). NOTE: Young birds that are one or two days old cannot activate the automatic watering cups. You must provide a small watering dish until they are old enough to activate the watering cup levers.

Feeding requirements:
The isolation unit includes a stainless steel "gravity fed" feeding unit. The unit will hold about 12 to 14 pounds of feed (5 to 6 kg) which should last eight to ten days, depending upon the age (size) of the fowl. Feed is introduced via the feed "chute"mounted on the front door.
Filter change over requirements:
The isolation unit is set up for negative pressure operation. Cages include two HEPA filters. One each at the air make up inlet and also the exhaust outlet. Pre-filters should be inspected weekly for dirt and "dander" build up. Pre-filters are very inexpensive and should be changed frequently. Pre-filters protect the more expensive HEPA filters. Both the pre-filters and main HEPA filters can be changed from out side the cage in just a few moments.

Waste pan change out:
Each isolation unit includes one waste pan. Pans are easily removed by opening the lower "trap door" and pulling out the pan.

Informations légales


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Questions

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique