93171

Diethylene glycol

BioUltra, ≥99.0% (GC)

Synonym(s):

2,2′-Oxydiethanol, 2-Hydroxyethyl ether, Bis(2-hydroxyethyl) ether, Diglycol

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice

About This Item

Linear Formula:
(HOCH2CH2)2O
CAS Number:
Molecular Weight:
106.12
UNSPSC Code:
12352137
NACRES:
NA.25
PubChem Substance ID:
EC Number:
203-872-2
Beilstein/REAXYS Number:
969209
MDL number:
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


grade

Molecular Biology

Quality Segment

vapor density

2.14 (vs air)

vapor pressure

0.01 mmHg ( 20 °C)

description

non-ionic

product line

BioUltra

assay

≥99.0% (GC)

form

liquid, viscous liquid

autoignition temp.

442 °F

mol wt

106.19 g/mol

expl. lim.

2-12.3 %

impurities

insoluble matter, passes filter test, ≤30 mg/kg peroxides (as H2O2)

refractive index

n20/D 1.447

pH

5.5-7.0 (25 °C, 50 mg/mL in H2O)

bp

245 °C (lit.)

mp

-10 °C, −10 °C (lit.)

solubility

H2O: 50 mg/mL at 20 °C, clear, colorless

density

1.118 g/mL at 25 °C (lit.)

anion traces

chloride (Cl-): ≤50 mg/kg, sulfate (SO42-): ≤50 mg/kg

SMILES string

OCCOCCO

cation traces

Al: ≤10 mg/kg, As: ≤0.1 mg/kg, Ba: ≤5 mg/kg, Bi: ≤5 mg/kg, Ca: ≤10 mg/kg, Cd: ≤5 mg/kg, Co: ≤5 mg/kg, Cr: ≤5 mg/kg, Cu: ≤5 mg/kg, Fe: ≤5 mg/kg, K: ≤200 mg/kg, Li: ≤5 mg/kg, Mg: ≤5 mg/kg, Mn: ≤5 mg/kg, Mo: ≤5 mg/kg, Na: ≤200 mg/kg, Ni: ≤5 mg/kg, Pb: ≤5 mg/kg, Sr: ≤5 mg/kg, Zn: ≤5 mg/kg

λ

50 mg/mL in H2O

UV absorption

λ: 260 nm Amax: ≤0.060, λ: 280 nm Amax: ≤0.030

InChI

1S/C4H10O3/c5-1-3-7-4-2-6/h5-6H,1-4H2

InChI key

MTHSVFCYNBDYFN-UHFFFAOYSA-N

Application

Diethylene glycol (diglycol) is used in biomaterials engineering to functionalize peptide nanofibers to improve their aggregation and proteolytic degradation properties. Diethylene glycol may be used as a solvent, reducing agent and derivatizing agent in the preparation of various types of nanoparticles.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
3216007-29208.03131
assay

≥99.0% (GC)

assay

≥99.0% (GC)

assay

≥98.0%

assay

-

grade

Molecular Biology

grade

-

grade

SAJ first grade

grade

synthesis grade

form

liquid, viscous liquid

form

viscous liquid (clear)

form

liquid

form

-

Quality Level

200

Quality Level

200

Quality Level

-

Quality Level

200

solubility

H2O: 50 mg/mL at 20 °C, clear, colorless

solubility

-

solubility

-

solubility

-

product line

BioUltra

product line

-

product line

-

product line

-


Still not finding the right product?

Explore all of our products under Diethylene glycol


pictograms

Exclamation mark

signalword

Warning

hcodes

Hazard Classifications

Acute Tox. 4 Oral

Storage Class

10 - Combustible liquids

wgk

WGK 1

flash_point_f

280.4 °F - closed cup

flash_point_c

138 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters