Skip to Content
Merck

Skip To

CDRM4HN05

Lynx® CDR

Lynx® CDR Male 1/2 Inch Hose Barb Reconnectable Connector - 5pack

Synonym(s):

Multiple aseptic connections, disconnections and reconnections (up to 6 times)

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice

About This Item

eCl@ss:
32010310
UNSPSC Code:
41121815
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

material

316 stainless steel spring(s) (electropolished, flow path), polysulfone flow path (glass filled ), polysulfone valve body (glass filled), silicone seal (flow path)

sterility

non-sterile

product line

Lynx®

parameter

0.7 bar max. pressure (10 psi) (connect/disconnect pressure), 2-40 °C operating temperature (36-104 °F), 4.1 bar max. pressure (60 psi) (operating pressure)

H

13.7 cm (5.4 in.)

L

25.7 cm (10.1 in.)

W

8.4 cm (3.3 in.)

fitting

1/2 in. inlet hose barb

Application

Multiple, sterile connections, disconnections and reconnections
Sterile connection of single-use systems

Legal Information

Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany
LYNX is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
CDRM4HG05CDRF8HN05CDRM6HG05
description

Lynx® CDR Male 1/2 Inch Hose Barb Reconnectable Connector - 5pack

description

Lynx® CDR Male 1/2 Inch Hose Barb Reconnectable Connector - 5pack - Irradiated

description

Lynx® CDR Female 1 Inch Hose Barb Reconnectable Connector - 5pack

description

Lynx® CDR Male 3/4 Inch Hose Barb Reconnectable Connector - 5pack - Irradiated

fitting

1/2 in. inlet hose barb

fitting

1/2 in. inlet hose barb

fitting

1 in. inlet hose barb

fitting

3/4 in. inlet hose barb

material

silicone seal (flow path), polysulfone valve body (glass filled), polysulfone flow path (glass filled ), 316 stainless steel spring(s) (electropolished, flow path)

material

polysulfone valve body (glass filled polysulfone USP Class VI, ADCF), polysulfone flow path (glass filled polysulfone USP Class VI, ADCF), polyethersulfone membrane (for vent), 316 stainless steel spring(s) (electropolished), seal (Silicone USP Class VI, ADCF or EMA/410/01 compliant), polysulfone housing (outer, sterility chamber)

material

316 stainless steel spring(s) (passivated), polysulfone flow path (glass filled polysulfone USP Class VI, ADCF), polysulfone housing (outer, sterility chamber), polysulfone valve body (glass filled polysulfone USP Class VI, ADCF), silicone seal (USP Class VI, ADCF or EMA/410/01 compliant)

material

polysulfone flow path (glass filled polysulfone USP Class VI, ADCF), seal (Silicone USP Class VI, ADCF or EMA/410/01 compliant), polyethersulfone membrane (for vent), 316 stainless steel spring(s) (electropolished), polysulfone housing (outer, sterility chamber), polysulfone valve body (glass filled polysulfone USP Class VI, ADCF)

product line

Lynx®

product line

Lynx®

product line

Lynx®

product line

Lynx®

sterility

non-sterile

sterility

irradiated

sterility

non-sterile

sterility

irradiated

parameter

4.1 bar max. pressure (60 psi) (operating pressure), 0.7 bar max. pressure (10 psi) (connect/disconnect pressure), 2-40 °C operating temperature (36-104 °F)

parameter

2-40 °C operating temperature (36-104 °F), 0.7 bar max. pressure (10 psi) (connect/disconnect pressure), 4.1 bar max. pressure (60 psi) (operating pressure)

parameter

4.1 bar max. pressure (60 psi) (operating pressure), 2-40 °C operating temperature (36-104 °F), 0.7 bar max. pressure (10 psi) (connect/disconnect pressure)

parameter

2-40 °C operating temperature (36-104 °F), 0.7 bar max. pressure (10 psi) (connect/disconnect pressure), 4.1 bar max. pressure (60 psi) (operating pressure)

Quality Level

400

Quality Level

400

Quality Level

400

Quality Level

400


Still not finding the right product?

Explore all of our products under Lynx® CDR




Stay compliant with GMP using the Emprove® Program

Accelerate qualification, maintain compliance, and save time with Emprove® Dossiers.

Download Dossiers

Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.

Register for free and access Emprove® Dossiers within minutes. Upgrade your subscription plan to unlock advanced and customized content in the Emprove® Suite

Not finding what you are looking for? Visit the Emprove® Program Help page.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.



Questions

Reviews

No rating value

Active Filters