Skip to Content
Merck
  • Method validation and application of a liquid chromatography-tandem mass spectrometry method for drugs of abuse testing in exhaled breath.

Method validation and application of a liquid chromatography-tandem mass spectrometry method for drugs of abuse testing in exhaled breath.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-02-18)
Niclas Stephanson, Sören Sandqvist, Marjan Shafaati Lambert, Olof Beck
ABSTRACT

A mass spectrometric method for drugs of abuse testing in exhaled breath employing a sampling device collecting aerosol particles was developed and applied in routine use. Analytes covered were amphetamine, methamphetamine, 6-acetylmorphine, morphine, cocaine, benzoylecgonine, diazepam, oxazepam and tetrahydrocannabinol. The method involved eluting drugs from the collection filter with methanol, quantification using deuterated analogs as internal standards, reversed phase chromatography with gradient elution, positive electrospray ionization and monitoring of two product ions per analyte in selected reaction monitoring mode. The measuring range was 6.0-1000pg/filter. The intra- and inter-assay imprecision expressed as the coefficient of variation was less than 7%. Influence from matrix was noted for most compounds but was compensated for the use of co-eluting internal standards. The LLOQ was 6.0pg/filter with intra-assay CV <5% and accuracy within 99-102% for all analytes. No chromatographic interference was observed in 20 negative control samples. The LC-MS/MS method was successfully applied for measuring drugs in unknown samples collected for the purpose of drug testing. Among the 1096 analyzed samples analytical findings were made in breath in 39 cases (3.6%). Most frequently found substances were the following: amphetamine (25 cases) methamphetamine (10 cases), THC (8 cases), cocaine (4 cases), benzoylecgonine (2 cases) and diazepam (2 cases). In conclusion, a fully validated and robust screening method suitable for the routine measurement of drugs of abuse in exhaled breath with a simple procedure for specimen collection and sample preparation was successfully developed.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile, for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrile, for chromatography
Supelco
2-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, ≥99.8%, for residue analysis, JIS 1000
Sigma-Aldrich
Formic acid, JIS special grade, ≥98.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
2-Propanol, SAJ first grade, ≥99.0%
Sigma-Aldrich
2-Propanol, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
2-Propanol, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%, poly coated bottles
Sigma-Aldrich
Cocaine free base
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
2-Propanol, anhydrous, 99.5%
Supelco
2-Propanol, analytical standard
Sigma-Aldrich
2-Propanol, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
2-Propanol, ACS reagent, ≥99.5%
Sigma-Aldrich
2-Propanol, 99.5%, HPLC grade
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Diazepam, European Pharmacopoeia (EP) Reference Standard
Supelco
Diazepam solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Oxazepam solution, 1 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
2-Propanol, suitable for HPLC