Skip to Content
Merck
All Photos(3)

Key Documents

227927

Sigma-Aldrich

Silver chloride

ReagentPlus®, 99%

Sign Into View Organizational & Contract Pricing


About This Item

Empirical Formula (Hill Notation):
AgCl
CAS Number:
Molecular Weight:
143.32
EC Number:
MDL number:
UNSPSC Code:
12352302
PubChem Substance ID:
NACRES:
NA.21
Assay:
99%
form:
powder or chunks
Pricing and availability is not currently available.

vapor pressure

1 mmHg ( 912 °C)

Quality Level

product line

ReagentPlus®

Assay

99%

form

powder or chunks

reaction suitability

reagent type: catalyst
core: silver

mp

455 °C (lit.)

SMILES string

Cl[Ag]

InChI

1S/Ag.ClH/h;1H/q+1;/p-1

InChI key

HKZLPVFGJNLROG-UHFFFAOYSA-M

Looking for similar products? Visit Product Comparison Guide

General description

Silver chloride (AgCl) is widely employed as a catalyst, photographic material, and ionic semiconductor material. High photosensitivity of AgCl makes it an important photocatalyst.

Application

Silver chloride can be used as a catalyst:
  • In the preparation of 1,2,3-triazoles from alkynes and azides.

Silver chloride is also be used:
  • As a precursor salt to synthesize silver nanoparticles.

Legal Information

ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictograms

CorrosionEnvironment

Signal Word

Warning

Hazard Statements

Precautionary Statements

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 1 - Met. Corr. 1

Storage Class Code

8B - Non-combustible corrosive hazardous materials

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Band structure of silver chloride and silver bromide.
Scop PM.
Physical Review, 139(3A), A934-A934 (1965)
Ionic conductivity of silver chloride single crystals.
Corish J and Jacobs PWM.
Journal of Physics and Chemistry of Solids, 33(7), 1799-1818 (1972)
A type of silver chloride electrode suitable for use in dilute solutions.
Brown AS.
Journal of the American Chemical Society, 56(3), 646-647 (1934)
Shaokun Zhang et al.
Toxicology in vitro : an international journal published in association with BIBRA, 27(2), 739-744 (2012-12-19)
Silver-containing antimicrobial agents are used in various medical products. However, their toxicity to mammalian cells has not been sufficiently evaluated. Numerous studies have unveiled evidence of significant antimicrobial properties associated with Ag ions. In cell culture media or human body
Jian-Feng Guo et al.
Journal of hazardous materials, 211-212, 77-82 (2011-12-20)
A new plasmonic photocatalyst of Ag-AgCl@TiO(2) was prepared by deposition-precipitation and photoreduction. This photocatalyst exhibited efficient photocatalytic activity for the degradation of 4-chlorophenol and photoreduction of Cr(VI) ion under visible light irradiation. Its high photocatalytic activity can be attributed to

Questions

1–2 of 2 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service