Skip to Content
Merck
All Photos(1)

Key Documents

I0320000

Insulin (porcine)

European Pharmacopoeia (EP) Reference Standard

Synonym(s):

Insulin from porcine pancreas, Insulin from hog pancreas

Sign Into View Organizational & Contract Pricing


About This Item

Empirical Formula (Hill Notation):
C256H381N65O76S6
CAS Number:
Molecular Weight:
5777.54
MDL number:
UNSPSC Code:
41116107
NACRES:
NA.24

grade

pharmaceutical primary standard

API family

insulin

manufacturer/tradename

EDQM

application(s)

pharmaceutical (small molecule)

format

neat

InChI key

NOESYZHRGYRDHS-ZYCCASTOSA-N

Looking for similar products? Visit Product Comparison Guide

General description

This product is provided as delivered and specified by the issuing Pharmacopoeia. All information provided in support of this product, including SDS and any product information leaflets have been developed and issued under the Authority of the Issuing Pharmacopoeia. For further information and support please go to the website of the issuing Pharmacopoeia.

Application

Insulin (porcine) EP Reference standard, intended for use in laboratory tests only as specifically prescribed in the European Pharmacopoeia.

Biochem/physiol Actions

Two-chain polypeptide hormone produced by the β-cells of pancreatic islets. Its molecular weight is ~5800 Da. The α and β chains are joined by two interchain disulfide bonds. The α chain contains an intrachain disulfide bond. Insulin regulates the cellular uptake, utilization, and storage of glucose, amino acids, and fatty acids and inhibits the breakdown of glycogen, protein, and fat.

Packaging

The product is delivered as supplied by the issuing Pharmacopoeia. For the current unit quantity, please visit the EDQM reference substance catalogue.

Other Notes

InChI: 1S/C256H381N65O76S6/c1-29-131(23)205(313-193(337)104-258)251(391)317-204(130(21)22)247(387)288-159(75-82-200(347)348)217(357)282-156(71-78-189(262)333)221(361)308-183-116-401-402-117-184-242(382)305-178(111-323)239(379)294-162(88-123(7)8)224(364)295-168(95-140-53-61-146(327)62-54-140)227(367)283-154(69-76-187(260)331)218(358)290-161(87-122(5)6)222(362)285-158(74-81-199(345)346)220(360)302-174(101-190(263)334)234(374)298-170(97-142-57-65-148(329)66-58-142)230(370)309-182(241(381)304-176(255(396)397)103-192(265)336)115-400-399-114-181(213(353)272-107-194(338)278-153(72-79-197(341)342)216(356)281-151(51-42-84-270-256(266)267)211(351)271-108-195(339)279-166(93-138-46-36-32-37-47-138)226(366)297-167(94-139-48-38-33-39-49-139)229(369)299-171(98-143-59-67-149(330)68-60-143)237(377)320-208(136(28)326)253(393)321-85-43-52-186(321)245(385)286-152(50-40-41-83-257)214(354)277-134(26)254(394)395)311-249(389)203(129(19)20)316-235(375)164(90-125(11)12)292-228(368)169(96-141-55-63-147(328)64-56-141)296-223(363)160(86-121(3)4)289-209(349)133(25)276-215(355)157(73-80-198(343)344)287-246(386)202(128(17)18)315-236(376)165(91-126(13)14)293-232(372)173(100-145-106-269-120-275-145)301-238(378)177(110-322)280-196(340)109-273-212(352)180(113-398-403-118-185(310-243(183)383)244(384)319-207(135(27)325)252(392)306-179(112-324)240(380)318-206(132(24)30-2)250(390)312-184)307-225(365)163(89-124(9)10)291-231(371)172(99-144-105-268-119-274-144)300-219(359)155(70-77-188(261)332)284-233(373)175(102-191(264)335)303-248(388)201(127(15)16)314-210(350)150(259)92-137-44-34-31-35-45-137/h31-39,44-49,53-68,105-106,119-136,150-186,201-208,322-330H,29-30,40-43,50-52,69-104,107-118,257-259H2,1-28H3,(H2,260,331)(H2,261,332)(H2,262,333)(H2,263,334)(H2,264,335)(H2,265,336)(H,268,274)(H,269,275)(H,271,351)(H,272,353)(H,273,352)(H,276,355)(H,277,354)(H,278,338)(H,279,339)(H,280,340)(H,281,356)(H,282,357)(H,283,367)(H,284,373)(H,285,362)(H,286,385)(H,287,386)(H,288,387)(H,289,349)(H,290,358)(H,291,371)(H,292,368)(H,293,372)(H,294,379)(H,295,364)(H,296,363)(H,297,366)(H,298,374)(H,299,369)(H,300,359)(H,301,378)(H,302,360)(H,303,388)(H,304,381)(H,305,382)(H,306,392)(H,307,365)(H,308,361)(H,309,370)(H,310,383)(H,311,389)(H,312,390)(H,313,337)(H,314,350)(H,315,376)(H,316,375)(H,317,391)(H,318,380)(H,319,384)(H,320,377)(H,341,342)(H,343,344)(H,345,346)(H,347,348)(H,394,395)(H,396,397)(H4,266,267,270)/t131-,132-,133-,134-,135+,136+,150-,151-,152-,153-,154-,155-,156-,157-,158-,159-,160-,161-,162-,163-,164-,165-,166-,167-,168-,169-,170-,171-,172-,173-,174-,175-,176-,177-,178-,179-,180-,181-,182-,183-,184-,185-,186-,201-,202-,203-,204-,205-,206-,207-,208-/m0/s1
Sales restrictions may apply.

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Sorry, we don't have COAs for this product available online at this time.

If you need assistance, please contact Customer Support.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Morten Donsmark et al.
Diabetes technology & therapeutics, 11(9), 581-585 (2009-09-22)
Easy-to-use insulin devices are an important tool in the treatment of diabetes. In this study, injection force requirements and dosage scale displays were evaluated for NovoPen 3 and NovoPen 4 (both from Novo Nordisk A/S, Copenhagen, Denmark). To simulate 5
László Deák
Orvosi hetilap, 153(40), 1589-1593 (2012-10-02)
The development of insulin therapy has not been stopped since the manufacturing of human insulin, because better mimic of physiological insulin response made it necessary to modify the human insulin molecule in order to create rapidly absorbing insulin analogues and
J S Christiansen et al.
Diabetes, obesity & metabolism, 12(2), 105-114 (2009-11-10)
Some patients with type 2 diabetes continue to have high postprandial blood glucose levels on twice-daily regimens of 'low-ratio' premix insulin formulations (up to 30% rapid-acting, with 70% protracted insulin). These patients require intensified insulin therapy, which can be provided
Rikke Due-Andersen et al.
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 10(2), 219-226 (2008-01-22)
Activity in the renin-angiotensin system (RAS) may influence the susceptibility to cardiac arrhythmia. To study the effect of basal RAS activity on cardiac repolarization during myocardial stress induced by hypoglycaemia or hypoxaemia in healthy humans. Ten subjects with high RAS
Arnaud Agin et al.
Clinical chemistry and laboratory medicine, 44(11), 1379-1382 (2006-11-08)
In clinical studies involving rapid-acting analogues (RAAs), insulin immunoreactivity is frequently measured, including endogenous, regular insulin (RI) and RAA immunoreactivities. Such a procedure implies equivalent cross-reactivities of all insulins present in serum. Commercially available human insulin immunoassays have been widely

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service