Opticap® XLT 30, cartridge L 34.3 in. (87.2 cm), filter diam. 2.7 in. (6.9 cm)
Synonyme(s) :
Gamma Opticap® XLT HBP 30 Express SHC TC/TC
About This Item
Produits recommandés
Matériaux
polyethersulfone filter (PES)
polyethylene support
polypropylene housing (PP)
silicon seal
Niveau de qualité
Conformité réglementaire
meets FDA CFR 210.3 (b) (6) (all component materials)
Stérilité
irradiated
non-sterile
Mode de stérilisation compatible
gamma compatible
Gamme de produits
Opticap® XLT 30
Caractéristiques
hydrophilic
Paramètres
1.0 bar max. inlet pressure (15 psi) at 80 °C
1000 mbar max. differential pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 °C
5500 mbar max. differential pressure (80 psi) at 25 °C
6.9 bar max. inlet pressure (100 psi) at 25 °C
76 L/min flow rate at 69 mbar (1 psi) and 23 °C
80 psig max. inlet pressure
Technique(s)
sterile filtration: suitable
Largeur
7.8 in.
cartridge L
34.3 in. (87.2 cm)
device size
30 in. (75 cm)
Diam. du filtre
2.7 in. (6.9 cm)
Surface de filtration
1.62 m2
Impuretés
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
Matrice
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
Point de bulle
≥4000 mbar (≥70 psig), air with water
Raccords
1/4 in. fitting (vent/drain hose barb with double O-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Device Configuration: Capsule
Conditionnement
Notes préparatoires
3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Remarque sur l'analyse
Autres remarques
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer to wetting instructions of Filters with Millipore Express® Membrane use guide
- Storage Statement: Please refer to Filters with Millipore Express® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Informations légales
Not finding the right product?
Try our Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique