Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

HTS160M

Sigma-Aldrich

ChemiSCREEN Membrane Preparation Recombinant Human BB 3 Bombesin Receptor

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41106514
eCl@ss :
32161000
Nomenclature NACRES :
NA.45

Source biologique

human

Niveau de qualité

Produit recombinant

expressed in Chem-1 cells

Forme

liquid

Fabricant/nom de marque

ChemiScreen
Chemicon®

Technique(s)

ligand binding assay: suitable (GTPγS)
radioligand binding assay (RLBA): suitable

Numéro d'accès NCBI

Numéro d'accès UniProt

Description générale

Bombesin, a bioactive peptide first identified in amphibian skin, is related to two mammalian peptides, gastrin-releasing peptide (GRP) and neuromedin B. A family of 3 GPCRs, including GRP-R (BB1), NMB-R (BB2) and BRS-3 (BB3), mediate the biological effects of the peptides (Ohki-Hamazaki et al., 2005). BB3 differs from the others by its low affinity for bombesin. Although an endogenous ligand for BB3 has yet to be identified, a synthetic nonselective bombesin-like peptide [H-D-Phe6, β-Ala11, Phe13, Nle14]-bombesin-(6-14)-nonapeptide amide (Bombesin (6-14) Analog) activates BB3 with high potency. BB3-null mice have an obese phenotype (Matsumoto and Iijima, 2003). Millipore′s BB3 membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of antagonists of BB3 receptor interactions with its ligand. The membrane preparations exhibit a Kd of 0.23nM for [125I]-Bombesin (6-14) Analog. With 10 μg/well BB3 Membrane Prep and 0.3 nM [125I]-Bombesin (6-14) Analog, a greater than 3-fold signal-to-background ratio was obtained.
Full length human BRS3 encoding BB3

Application

Human BB3 GPCR membrane preparation for Radioligand binding Assays & GTPγS binding.
Radioligand binding assay and GTPγS binding

Actions biochimiques/physiologiques

  • GPCR Class: A
  • Protein Target: BB3
  • Target Sub-Family: Bombesin

Caractéristiques

Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h.Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4,0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer.The plate is dried and counted.

Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, 0.2 mg/ml bacitracin, 20 μg/ml leupeptin, 20 μg/ml chymostatin, 1 Protease Inhibitor cocktail Tablets (Roche Cat. No. 11 873 580 001) for each 50 ml binding buffer.

Radioligand: [125I]-Bombesin (6-14) Analog (Perkin Elmer NEX377)

Wash Buffer: 50 mM Hepes, pH 7.4, 500 mM NaCl , 0.1% BSA, filtered and stored at 4°C.

One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 3-fold signal:background with 125I-labeled Bombesin (6-14) Analog at 0.3 nM.

Forme physique

Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives.
Packaging method: Membranes protein was adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80oC.

Stockage et stabilité

Maintain frozen at -70°C for up to 2 years. Do not freeze and thaw.

Informations légales

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 2


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique