HMHEMAG-34K
MILLIPLEX® Human Metabolic Hormone Magnetic Bead Panel - Metabolism Multiplex Assay
The Human Metabolic Hormone Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 13 protein biomarkers in human serum, plasma and cell/tissue culture samples.
Synonyme(s) :
human metabolic hormone immunoassay panel, luminex human metabolic hormone multiplex assay, millipore human metabolism multiplex kit
About This Item
Produits recommandés
Espèces réactives
human
Fabricant/nom de marque
Milliplex®
assay range
accuracy: 101%
(Glucagon)
accuracy: 102%
(Leptin)
accuracy: 103%
(GIP)
accuracy: 103%
(GLP-1 (Total))
accuracy: 105%
(Ghrelin (Active))
accuracy: 106%
(MCP-1)
accuracy: 97%
(TNFα)
accuracy: 99%
(C-Peptide)
sensitivity: 0.5 pg/mL
(MinDC+2SD; TNF?)
sensitivity: 1.1 pg/mL
(MinDC+2SD; GIP)
sensitivity: 13 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 14 pg/mL
(MinDC+2SD; Ghrelin (Active))
sensitivity: 14 pg/mL
(MinDC+2SD; MCP-1)
sensitivity: 146 pg/mL
(MinDC+2SD; PYY)
sensitivity: 15 pg/mL
(MinDC+2SD; Amylin (Total))
sensitivity: 16 pg/mL
(MinDC+2SD; C-Peptide)
sensitivity: 16 pg/mL
(MinDC+2SD; Glucagon)
sensitivity: 160 pg/mL
(MinDC+2SD; Insulin)
sensitivity: 2.4 pg/mL
(MinDC+2SD; GLP-1 (Active))
sensitivity: 2.9 pg/mL
(MinDC+2SD; PP)
sensitivity: 28 pg/mL
(MinDC+2SD; Amylin (Active))
sensitivity: 64 pg/mL
(MinDC+2SD; Leptin)
sensitivity: 7.3 pg/mL
(MinDC+2SD; GLP-1 (Total))
standard curve range: 0.69-500 pg/mL
(TNFα)
standard curve range: 1.4-1,000 pg/mL
(GIP)
standard curve range: 13.7-10,000 pg/mL
(Amylin (Active))
standard curve range: 13.7-10,000 pg/mL
(Amylin (Total))
standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active))
standard curve range: 13.7-10,000 pg/mL
(Glucagon)
standard curve range: 13.7-10,000 pg/mL
(IL-6)
standard curve range: 13.7-10,000 pg/mL
(MCP-1)
standard curve range: 13.7-10,000 pg/mL
(PYY)
standard curve range: 137-100,000 pg/mL
(Insulin)
standard curve range: 137-100,000 pg/mL
(Leptin)
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Active))
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Total))
standard curve range: 2.7-2,000 pg/mL
(PP)
standard curve range: 27.4-20,000 pg/mL
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(GIP)
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Total))
inter-assay cv: <15%
intra-assay cv: <10%
(Ghrelin (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(Glucagon)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(Leptin)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(PP)
inter-assay cv: <15%
intra-assay cv: <10%
(PYY)
inter-assay cv: <15%
intra-assay cv: <10%
(TNFα)
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Active))
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Total))
Technique(s)
multiplexing: suitable
Méthode de détection
fluorometric (Luminex xMAP)
Conditions d'expédition
wet ice
Description générale
The MILLIPLEX® Human Metabolic Hormone Panel is a 15 analyte, 13-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and cell/tissue culture samples: Amylin (Active) or Amylin (Total), C-Peptide, Ghrelin (Active), GIP, GLP-1 (Active) or GLP-1 (Total), Glucagon, IL-6, Insulin, Leptin, MCP-1, PP, PYY, TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Application
- Analytes: Amylin (Active), Amylin (Total), C-Peptide, Ghrelin (Active), GIP (Total), GLP-1 (Active), GLP-1 (Total), Glucagon, IL-6, Insulin, Leptin, MCP-1 (CCL2), Pancreatic Polypeptide (PP), PYY (Total), TNF-α
- NOTE: The following analytes cannot be assayed simultaneously: Amylin (Active) & Amylin (Total); GLP-1 (Active) & GLP-1 (Total).
- Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma; cell/tissue culture samples may be used undiluted or diluted with an appropriate control medium NOTE: The following analytes require the addition of protease inhibitors to serum or plasma samples (see sample collection and storage section in the protocol for details): GLP-1 (DPPIV inhibitor); Amylin (protease inhibitor cocktail); Glucagon (Aprotinin); Ghrelin (Active) (serine protease inhibitor).
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Metabolic Disorders
Caractéristiques et avantages
Liaison
Autres remarques
Informations légales
Mention d'avertissement
Danger
Mentions de danger
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
Code de la classe de stockage
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Contenu apparenté
Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique