Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

E-008

Supelco

Ecgonine methyl ester solution

100 μg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®

Synonyme(s) :

Ecgonine methyl ester

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C10H17NO3
Numéro CAS:
Poids moléculaire :
199.25
Numéro CE :
Code UNSPSC :
41116107
Nomenclature NACRES :
NA.24

Qualité

certified reference material

Forme

liquid

Caractéristiques

Snap-N-Spike®/Snap-N-Shoot®

Conditionnement

ampule of 1 mL

Fabricant/nom de marque

Cerilliant®

drug control

Narcotic Licence Schedule A (Switzerland); estupefaciente (Spain); Decreto Lei 15/93: Tabela IB (Portugal)

Concentration

100 μg/mL in acetonitrile

Technique(s)

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

Application(s)

forensics and toxicology

Format

single component solution

Température de stockage

−20°C

InChI

1S/C10H17NO3/c1-11-6-3-4-7(11)9(8(12)5-6)10(13)14-2/h6-9,12H,3-5H2,1-2H3/t6?,7?,8-,9+/m0/s1

Clé InChI

QIQNNBXHAYSQRY-ABIFROTESA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

A certified Snap-N-Spike® solution standard suitable for use in LC/MS or GC/MS testing applications including forensic analysis, urine drug testing, and clinical toxicology. Ecgonine methyl ester is a major urinary metabolite of cocaine, a popular illicit drug well known as "crack" or the free base form of cocaine that can be smoked.

Informations légales

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Pictogrammes

FlameExclamation mark

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

35.6 °F - closed cup

Point d'éclair (°C)

2 °C - closed cup


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

C Pistos et al.
Rapid communications in mass spectrometry : RCM, 23(23), 3772-3780 (2009-11-11)
At present, no official criteria exist for drug identification using single quadrupole mass spectrometers although the European Union (EU) criteria for compound identification have been adopted. These criteria are evaluated with respect to the confirmation of cocaine and its metabolites
Rosa Cordero et al.
Journal of analytical toxicology, 34(9), 543-548 (2010-11-16)
The concentrations and ratios of cocaine, benzoylecgonine (BE), and ecgoninemethylester (EME) in 360 head hair segments and 34 pubic hair samples collected at coroner's postmortem examinations were reviewed. The cases included diverse histories and causes/circumstances of death. The hair was
Marta Concheiro et al.
Journal of analytical toxicology, 31(9), 573-580 (2007-12-21)
A method, using 0.5 mL of urine, was developed for the simultaneous determination of ecgonine methyl ester, benzoylecgonine, morphine, codeine, 6-acetylmorphine, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), and d-lysergic acid diethylamide (LSD). The analysis was performed by
Cláudia Margalho et al.
Journal of forensic and legal medicine, 18(3), 132-135 (2011-03-23)
Postmortem tissues (e.g. liver, kidney) have been long used in forensic applications especially in those cases where blood is unavailable. The aim of this paper is to demonstrate the importance of the information provided to the forensic toxicologist at the
Xiaobo Wang et al.
Se pu = Chinese journal of chromatography, 28(7), 673-676 (2010-11-05)
A method was developed for the simultaneous determination of cocaine (COC) and its metabolite ecgonine methyl ester (EME) in human blood using gas chromatography-mass spectrometry (GC-MS) and gas chromatography-flame ionization detection (GC-FID). The blood sample was prepared by microwave extraction

Questions

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique