Yes, extending the spin times is sufficient. However, the time range would have to be experimentally determined by the user.
Größe auswählen
| Ihnen/SKU | Verfügbarkeit | Preis |
|---|---|---|
8 pkg | Warenkorb auf Verfügbarkeit prüfen | € 109,00 |
24 pkg | Warenkorb auf Verfügbarkeit prüfen | € 298,00 |
96 pkg | Warenkorb auf Verfügbarkeit prüfen | € 834,00 |
Über diesen Artikel
Quality Segment
material
polyethylene cap, polyethylene liner, polypropylene tube, regenerated cellulose membrane, regenerated cellulose support, styrene-butadiene housing
sterility
non-sterile
product line
Amicon®
packaging
pkg of 24 pkg, pkg of 8 pkg, pkg of 96 pkg
manufacturer/tradename
Amicon® Ultra
sustainability
Greener Alternative Product
parameter
4 mL sample volume
technique(s)
protein extraction: suitable, protein purification: suitable
L
124 mm (4.88 in.)
diam.
17.3 mm
filtration area
3 cm2
volume
4 mL
working volume
≤4 mL , 4 mL
pore size
10 kDa MWCO
greener alternative category
shipped in
ambient
General description
Das vertikale Design und die verfügbare Membranoberfläche bieten eine schnelle Probenverarbeitung, hohe Probenrückgewinnung (in der Regel mehr als 90 % der verdünnten Ausgangslösung) und die Möglichkeit für eine 80-fache Konzentration. Die Polarisation der gelösten Stoffe und anschließendes Fouling der Membran werden durch das vertikale Design minimiert und ein physischer Dead Stop in der Filtervorrichtung verhindert das Zentrifugieren bis zur Austrocknung und einen potenziellen Probenverlust.
Das Konzentrat wird mit einem Pipettierer aus dem Probenreservoir der Filtervorrichtung entnommen, während das Ultrafiltrat in dem bereitgestellten Zentrifugenröhrchen gesammelt wird. Die Vorrichtung kann mit einem Schwenkwinkel- oder Festwinkelrotor verwendet werden. Durch das vertikale Membrandesign und den Dead Stop können die Amicon® Ultra 15-ml-Filter die höchste Rückgewinnung bei kurzen Abschleuderzeiten bieten.
Application
- Ultrafiltration mit einer Ultracel®-Membran mit 10.000-Dalton-Molekulargewichtsausschlussgrenze.
- Konzentration von biologischen Proben, die Antigene, Antikörper, Enzyme, Nukleinsäuren oder Mikroorganismen enthalten.
- Aufreinigung von makromolekularen Komponenten aus Gewebekulturextrakten oder Zelllysaten und Proteinentfernung vor der HPLC.
- Konzentration von verdünnten oder vor-aufgereinigten Proteinen aus Säuleneluenten.
- Entsalzung, Pufferaustausch und Proteindialyse.
- Größenausschluss und Proteinfraktionierung.
Features and Benefits
- Ultracel® regenerierte Cellulosemembran mit 10-kDa-NMWCO ermöglicht eine Retentatrückgewinnung von mehr als 90 %.
- Die vertikale Membran verringert die Konzentrationspolarisation für ultraschnelle Abschleuderzeiten (innerhalb 5 Minuten).
- Die heißversiegelte Membran minimiert die Downstream-Extractables.
- 100 % integritätsgeprüft für eine verlässliche Leistung.
- Praktische Probenüberwachung mit einem transparenten Gehäuse und Skaleneinteilung für das Volumen.
- Direkter Probenzugang für die Pipette eliminiert den Verarbeitungsschritt, um das Konzentrat zu gewinnen.
- Hohe Konzentrationsfaktoren von 80–100 X.
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| description sample volume 4 mL, regenerated cellulose membrane, MWCO 10 kDa | description sample volume 2 mL, regenerated cellulose membrane, MWCO 10 kDa | description sample volume 15 mL, regenerated cellulose membrane, MWCO 10 kDa | description sample volume 0.5 mL, regenerated cellulose membrane, MWCO 10 kDa |
| manufacturer/tradename Amicon® Ultra | manufacturer/tradename Amicon® Ultra | manufacturer/tradename Amicon® Ultra | manufacturer/tradename Amicon® Ultra |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
| pore size 10 kDa MWCO | pore size 10 kDa MWCO | pore size 10 kDa MWCO | pore size 10 kDa MWCO |
| parameter 4 mL sample volume | parameter 2 mL sample volume | parameter 15 mL sample volume | parameter 0.5 mL sample volume |
| material polyethylene cap, polypropylene tube, regenerated cellulose support, polyethylene liner, styrene-butadiene housing, regenerated cellulose membrane | material polypropylene tube (for collection), regenerated cellulose membrane, styrene-butadiene housing | material polyethylene cap, polyethylene liner, polypropylene tube, regenerated cellulose membrane, regenerated cellulose support, styrene-butadiene housing | material polypropylene cap, polypropylene tube, regenerated cellulose membrane, styrene-butadiene housing |
| working volume ≤4 mL | working volume ≤2 mL | working volume ≤15 mL | working volume ≤500 μL , 0.5 mL |
Still not finding the right product?
Explore all of our products under Amicon® Ultra Zentrifugenfilter, 10 kDa MWCO
Lagerklasse
10-13 - German Storage Class 10 to 13
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
-
If my centrifuge only goes to 3,052 g, is it okay to centrifuge for a longer period of time to get the same separation? It is a swing-bucket centrifuge using the 10 MWCO filters.
1 answer-
Helpful?
-
-
is-it possible to wash and re-use the Amicon@Ultra-4 ? if yes how many time is_it possible to use them ?
1 answer-
The unit is for one-time use only.
Helpful?
-
-
How should the tubes be sterilized without damaging the membrane?
1 answer-
There are no validated sterilization methods for the Amicon Ultra devices. However, these devices can be "sanitized" with a spin cycle with 70% ethanol, followed by 2 rinsing spins with sterile water. It is recommended to filter the concentrated sample using a sterile 0.2 µm syringe filter (e.g., SLGVR33RS) after processing on the Amicons.
Helpful?
-
-
What speed can this product be centrifuged at ?
1 answer-
For this item when using a swinging-bucket rotor, spin the device at 4,000 × g maximum for approximately 10-40 minutes. When using a fixed-angle rotor, orient the device with the membrane panel facing up. For Amicon® Ultra 3K, 10K, 30K, and 50K devices, spin at 7,500 × g maximum for approximately 10-40 minutes. For Amicon® Ultra 100K devices, spin at 5,000 × g maximum for approximately 10-20 minutes.
Helpful?
-
-
How to use it...how much sample should be loaded and what will be the protocol of centrifugation while using?
1 answer-
The maximum initial sample 4 volume (mL). For more information please see page 36 in this product https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/260/181/br5002en-protein-prep-workflow-ms.pdf
Helpful?
-