The Human Adiponectin ELISA (EZHADP-61K) can be used with serum samples (red top tubes) and EDTA plasma (lavender top tubes)
Größe auswählen
| Ihnen/SKU | Verfügbarkeit | Preis |
|---|
Über diesen Artikel
sample type plasma (K2 EDTA)
(adiponection)
Produktname
Human Adiponectin ELISA, This Human Adiponectin ELISA is used to measure & quantify Adiponectin levels in Metabolism & Endocrine research.
Quality Segment
species reactivity
human
packaging
kit of 1 × 96 wells
parameter
20 μL sample volume (4hr assay)
assay range
accuracy: 92-102%, intra-assay cv: 1.0-7.4, linearity: 81-100%, sensitivity: 1.5 ng/mL, standard curve range: 1.5-100 ng/mL
(adiponection)
technique(s)
ELISA: suitable
input
sample type serum
sample type plasma (K2 EDTA)
NCBI accession no.
UniProt accession no.
application(s)
research use
detection method
colorimetric (450nm/590nm)
shipped in
wet ice
storage temp.
2-8°C
Gene Information
human ... ADIPOQ(9370)
General description
Application
Metabolism
Obesity
Metabolic Disorders
Other Notes
Disclaimer
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| species reactivity human | species reactivity mouse | species reactivity human | species reactivity human |
| Gene Information human ... ADIPOQ(9370) | Gene Information mouse ... ADIPOQ(11450) | Gene Information human ... IAPP/AMYLIN/IAP/Amylin/DAP(1611) | Gene Information - |
| assay range accuracy: 92-102%, linearity: 81-100%, standard curve range: 1.5-100 ng/mL | assay range accuracy: 99-112%, linearity: 96-121%, sensitivity: 0.78 ng/mL, standard curve range: 0.78-50 ng/mL | assay range - | assay range accuracy: 76-103%, linearity: 96-112%, standard curve range: 2-200 μU/mL |
| input sample type serum | input sample type plasma (K2 EDTA) | input sample type plasma (K2 EDTA) | input sample type plasma (K2 EDTA) |
| Quality Level 200 | Quality Level 200 | Quality Level 200 | Quality Level 200 |
| detection method colorimetric (450nm/590nm) | detection method colorimetric (450nm/590nm) | detection method fluorometric (355nm/460nm) | detection method colorimetric (450nm) |
signalword
Danger
Hazard Classifications
Acute Tox. 2 Dermal - Acute Tox. 2 Inhalation - Acute Tox. 3 Oral - Aquatic Chronic 2 - Met. Corr. 1 - Skin Sens. 1 - STOT RE 2 Oral
target_organs
Brain
supp_hazards
Lagerklasse
6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials
wgk
WGK 3
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
-
Dear Sir With regard to 'Specimen Requirements' which, test tube colour [Container] should we use when collecting the blood sample: Red-top tube, gel-barrier tube, or lavender-top (EDTA) tube??? Looking forward to hearing from you ASAP. Kind regards
1 answer-
Helpful?
-