Fortfahren mit
Größe auswählen
| Ihnen/SKU | Verfügbarkeit | Preis |
|---|---|---|
1 ea |
Über diesen Artikel
Dieser Artikel kann nicht von einem Gastbenutzer erworben werden. Um weitere Informationen zu erhalten, kontaktieren Sie uns bitte unter +43 1 3602 77 47 43oder
.Quality Segment
material
polyethersulfone membrane, polypropylene housing, polypropylene support, polypropylene vent cap
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
autoclavable compatible
steam-in-place compatible
product line
EMPROVE® Filter, Milligard®
feature
hydrophilic
manufacturer/tradename
Milligard®
parameter
1.38 bar max. differential pressure (20 psid) at 25 °C (Reverse), 5.52 bar max. differential pressure (80 psid) at 4-25 °C (Forward)
technique(s)
bioburden reduction: suitable
L
31.8 in.
W
2.7 in.
cartridge nominal length
30 in. (75 cm)
diam.
69 mm (2.71 in.)
filtration area
1.8 m2
impurities
<0.25 EU/mL bacterial endotoxins (LAL test, per device; aqueous extraction; meeting requirements of USP <85>, EP 2.6.14 and JP 4.01)
matrix
Milligard® PES
pore size
1.2/0.2 μm nominal pore size, 1.2/0.2 μm pore size
input
sample type liquid
cartridge code
Code 7
General description
Preparation Note
Autoclave wet 25x, 60 minute cycles at 128°C. In-line steam (wet): 10 forward cycles, 30 min.,
135 °C at ≤0.34 bar (5 psid) and 5 reverse cycles,
30 min., 135 °C at ≤0.07 bar (<1 psid)*.
*Devices were validated using steam at full differential pressure starting at 31 psid to a final differential pressure of 1 psid, resulting in a calculated average of 4 psid in forward and reverse directions.
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIGARD® PES Membrane user guide
- Storage Statement: Please refer Filters with MILLIGARD® PES Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| pore size 1.2/0.2 μm nominal pore size, 1.2/0.2 μm pore size | pore size 1.2/0.2 μm nominal pore size, 1.2/0.2 μm pore size | pore size 1.2/0.45 μm pore size | pore size 1.2/0.2 μm nominal pore size, 1.2/0.2 μm pore size |
| product line EMPROVE® Filter, Milligard® | product line EMPROVE® Filter, Milligard® | product line EMPROVE® Filter, Milligard® | product line EMPROVE® Filter, Milligard® |
| filtration area 1.8 m2 | filtration area 1.20 m2 | filtration area 1.8 m2 | filtration area 0.6 m2 |
| technique(s) bioburden reduction: suitable | technique(s) bioburden reduction: suitable | technique(s) prefiltration: suitable | technique(s) bioburden reduction: suitable |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
| matrix Milligard® PES | matrix Milligard® PES | matrix Milligard® PES | matrix Milligard® PES |
Still not finding the right product?
Explore all of our products under Milligard® PES, 1,2/0,2 µm nominal, Kartusche
Bleiben Sie mit dem Emprove®-Programm GMP-konform
Beschleunigen Sie die Qualifizierung, halten Sie die Vorschriften ein und sparen Sie Zeit mit Emprove® Dossiers.
Hinweis: Sie werden zu EmproveSuite.com weitergeleitet. Ihr Benutzername und Passwort sind von SigmaAldrich.com getrennt und können abweichen.
Registrieren Sie sich kostenlos und erhalten Sie innerhalb weniger Minuten Zugang zu Emprove® Dossiers. Aktualisieren Sie Ihr Abonnement, um erweiterte und angepasste Inhalte in der Emprove® Suite freizuschalten.
Sie finden nicht, was Sie suchen? Besuchen Sie die Emprove® Programm-Hilfeseite.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.