Saltar al contenido
Merck
  • Amylase α-1A (AMY1A): a novel immunohistochemical marker to differentiate chromophobe renal cell carcinoma from benign oncocytoma.

Amylase α-1A (AMY1A): a novel immunohistochemical marker to differentiate chromophobe renal cell carcinoma from benign oncocytoma.

The American journal of surgical pathology (2013-11-15)
Sarika Jain, Somak Roy, Milon Amin, Marie Acquafondata, Ming Yin, William Laframboise, Sheldon Bastacky, Liron Pantanowitz, Rajiv Dhir, Anil Parwani
RESUMEN

Chromophobe renal cell carcinoma (ChRCC) and oncocytoma present with a perplexing overlap of morphologic and immunohistochemical features. ChRCC have deletions in the 1p21.1 region including the amylase α-1A gene (AMY1A). No such deletions are found in oncocytoma. Instead, oncocytomas shared other deletions on chromosome 1: 1p31.3, 1q25.2, and 1q44. We performed AMY1A immunostaining on 75 oncocytomas (57 tissue microarray [TMA] cores, 18 whole slides) and 54 ChRCCs (20 TMA cores, 34 whole slides). Staining was assessed using the H-score method. The intensity was graded as follows: no staining=0, weak=1, moderate=2, and strong=3. The AMY1A immunostain preferentially stained the distal tubules and collecting ducts of normal kidney. All oncocytomas (100%) expressed AMY1A with an H-score that varied from 100 to 300 (mean 205). Mild to moderate heterogeneity in staining intensity was noted within a given oncocytoma. For oncocytomas, 87% (65/75) cases had H-scores of at least 120 with a mean score of 221. Notably, the 13% (10/75) of oncocytoma cases that had an H-score of 100 were derived from the TMA. A total of 87% (47/54) of the ChRCC cases were negative for the AMY1A immunostain. Of the ChRCC cases, 4% (2/54) showed very weak cytoplasmic staining (H-score of 70 each), which was less than the lowest H-score of oncocytoma cases. All 5 cases of ChRCC, which showed an H-score of 100 or more, were referred to as eosinophilic variants of ChRCC. Three of these 5 cases showed a very nondescript, diffuse staining of the cytoplasm. Two of these 5 cases showed an H-score of 130. We think that as the staining pattern of these 2 cases is similar to that of oncocytoma, they should be put in a category of renal oncocytic neoplasms favoring oncocytoma. This result shows that AMY1A staining could be very helpful in further classifying even a subset of the eosinophilic variants of ChRCC. The difference between ChRCC and oncocytoma was statistically significant (χ test, P<0.0001). All cases of clear cell RCC and papillary RCC were negative for AMY1A expression. Overall, sensitivity and specificity of AMY1A staining for oncocytoma was 100% (95% confidence interval, 0.95-1.00) and 96.75% (95% confidence interval, 0.93-0.99), respectively. Similarly, the sensitivity and specificity for distinguishing oncocytoma from ChRCC was 100% (95% confidence interval, 0.95-1.00) and 90.74% (95% confidence interval, 0.80-0.97), respectively. These data show that the novel marker AMY1A can be of great diagnostic utility when trying to differentiate ChRCC (classic and eosinophilic variant) and oncocytoma.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
αα-Amilasa termoestable, solution, for use in Total Dietary Fiber Assay, TDF-100A
Sigma-Aldrich
αα-Amilasa from human saliva, Type XIII-A, lyophilized powder, 300-1,500 units/mg protein
Sigma-Aldrich
α-Amylase from porcine pancreas, Type VI-B, ≥5 units/mg solid
Sigma-Aldrich
Taka-diastasa from Aspergillus oryzae, powder, slightly beige, ~100 U/mg
Sigma-Aldrich
αα-Amilasa from Aspergillus oryzae, powder, ~30 U/mg
Sigma-Aldrich
αα-Amilasa from Bacillus licheniformis, Type XII-A, saline solution, ≥500 units/mg protein (biuret)
Sigma-Aldrich
αα-amilasa from Bacillus sp., Type II-A, lyophilized powder, ≥1,500 units/mg protein (biuret)
Sigma-Aldrich
αα-Amilasa from Aspergillus oryzae, ≥150 units/mg protein (biuret)
Sigma-Aldrich
αα-Amilasa from Bacillus licheniformis, lyophilized powder, 500-1,500 units/mg protein, 93-100% (SDS-PAGE)
Sigma-Aldrich
αα-Amilasa from human saliva, Type IX-A, lyophilized powder, 1,000-3,000 units/mg protein
Sigma-Aldrich
α-Amylase from Bacillus sp., powder, yellow-brown, ~50 U/mg
Sigma-Aldrich
αα-Amilasa from Aspergillus oryzae, powder, ~1.5 U/mg (~0.2 U acc. to Willstätter)
Sigma-Aldrich
α-Amylase from Bacillus sp., liquid
Sigma-Aldrich
α-Amylase from porcine pancreas, PMSF Treated, Type I-A, saline suspension, ≥1000 units/mg protein (E1%/280)
Sigma-Aldrich
αα-amilasa from Bacillus sp., powder, ≥400 units/mg protein (Lowry)
Sigma-Aldrich
αα-Amilasa from Aspergillus oryzae, aqueous solution, ≥800 FAU/g
Sigma-Aldrich
α-Amylase from Bacillus amyloliquefaciens, liquid, ≥250 units/g
Sigma-Aldrich
α-Amylase from Bacillus sp., powder, yellow-brown, ~380 U/mg
Sigma-Aldrich
α-Amylase from porcine pancreas, Type I-A, PMSF treated, saline suspension, 700-1400 units/mg protein (E1%/280)
Supelco
αα-Amilasa from Bacillus licheniformis, suitable for determination of starch (Kit STA-20)