AA0100

Sigma-Aldrich

Ammonia Assay Kit

sufficient for 100 assays

Sinónimos:

Ammonia Quantitative Test Kit

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
12352202
NACRES:
NA.84
En este momento no podemos mostrarle ni los precios ni la disponibilidad

uso

sufficient for 100 assays

temp. de almacenamiento

2-8°C

Aplicación

Ammonia concentration was measured in serum and urine using the Sigma Ammonia Assay Kit in a study assessing expression of renal ammonia transporters in response to chromic metabolic acidosis. [1]
This kit is for the quantitative, enzymatic determination of ammonia in food and biological samples. Ammonia reacts with α-ketoglutaric acid (KGA) and reduced nicotinamide adenine dinucleotide phosphate (NADPH) in the presence of L-glutamate dehydrogenase (GlDH) to form L-glutamate and oxidized nicotinamide adenine dinucleotide phosphate (NADP+). The decrease in absorbance at 340 nm, due to the oxidation of NADPH, is proportional to the ammonia concentration. L-Glutamate dehydrogenase reacts specifically with ammonia. The Ammonia Assay Kit may be used to determine ammonia concentrations in the range of 0.2-15 μg/ml.

Solo componentes del kit

Referencia del producto
Descripción

  • Ammonia Assay Reagent 10 vial(s)

  • L-Glutamate Dehydrogenase for Ammonia Assay 1 mL/vial

  • Ammonia Standard Solution 1 mL/vial

Pictogramas

Health hazard

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Eye Irrit. 2 - Resp. Sens. 1

Código de clase de almacenamiento

10 - Combustible liquids

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Na Gao et al.
Fish & shellfish immunology, 65, 226-234 (2017-04-22)
Ammonia is highly toxic to aquatic organisms, but whether ammonia excretion or ammonia metabolism to less toxic compounds is the major strategy for detoxification in marine fish against chronic ammonia exposure is unclear to date. In this study, we investigated
Kahina Mellahi et al.
Bioprocess and biosystems engineering, 42(5), 711-725 (2019-01-24)
Mammalian-inducible expression systems are increasingly available and offer an attractive platform for the production of recombinant proteins. In this work, we have conducted process development for a cumate-inducible GS-CHO cell-line-expressing rituximab. To cope with the limitations encountered in batch when
Kahina Mellahi et al.
Journal of biotechnology, 298, 45-56 (2019-04-09)
In order to maximize cell growth and productivity for an inducible CHO cell line expressing rituximab, various fed-batch culture strategies were investigated. In each case, the performance was evaluated for cultures induced at moderate and high cell density conditions (4 × 106
W E Neeley et al.
Clinical chemistry, 34(9), 1868-1869 (1988-09-01)
This is an automated, cost-efficient enzymatic method for determining ammonia in plasma. In most assays for ammonia the reagents are stable for only one or two days at 4 degrees C, but the reagents in our method are stable for

Artículos

Sigma article discusses tumor cell metabolic pathways, focusing on aerobic glycolysis and mitochondrial activity.

Fatty acid synthesis supports cancer cell proliferation, essential for membrane generation, protein modification, and bioenergetics.

Questions

1–8 of 8 Questions  
  1. Can we use this kit for microplate reader system

    1 answer
    1. The protocol below has not been tested but is based on adaptations of the reagents to similar instruments.
      In order to perform the assay in a microplate instead of cuvettes, the reagent and sample volumes can be reduced by a factor of 5. Thus, the reagent volume would be 200 microliters; the volume of water or sample would be 20 microliters, and the volume of standard would be 10 microliters. The required volume of the enzyme solution would decrease to 2 microliters, which is difficult to pipette accurately. To deliver the enzyme more accurately, dilute it 5x P5244 using Phosphate Buffer, pH 7.5, as the enzyme diluent and pipette 10 microliters into each well.

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  4. In the case of bacterial culture supernatant (BHI broth), should the decolorization process be performed? How?

    1 answer
    1. Any sample solution that is strongly colored and/or has a low ammonia concentration should be decolorized when using this kit. Colored sample solutions often are treated with decolorizing carbon (activated charcoal) to remove color-contributing impurities.

      Helpful?

  5. Is there a control that can be used to assess the accuracy of Product AA0100, Ammonia Assay Kit?

    1 answer
    1. A convenient control for use with this kit is the Ammonia Standard Solution that is provided in the kit.

      Helpful?

  6. How can I assess the absorbance change of my reagent blank when using Product AA0100, Ammonia Assay Kit?

    1 answer
    1. Generally, an absorbance change of 0.050 or less indicates an acceptable range for the reagent blank. An absorbance change higher than this indicates possible contamination of the reagent (or glassware) with ammonia.

      Helpful?

  7. Which samples should be deproteinized for use with Product AA0100, Ammonia Assay Kit?

    1 answer
    1. The basis for this kit was a Diagnostic procedure for the determination of Ammonia in human plasma, whose total protein concentration is approximately 63 to 83 mg/mL. Thus, any solution whose protein concentration is less than approximately 83 mg/mL should not require deproteinization.

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico