900667
Acetonitrile
≥99.92%, suitable for mass spectrometry (MS), UHPLC
Synonym(s):
ACN, Cyanomethane, Ethyl nitrile, Methyl cyanide
Select a Size
Select a Size
About This Item
Recommended Products
product name
Acetonitrile, for UHPLC, suitable for mass spectrometry (MS)
Agency
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 8327
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
Quality Level
reg. compliance
suitable for FDA C-010.02
vapor density
1.41 (vs air)
vapor pressure
72.8 mmHg ( 20 °C)
Assay
≥99.92%
form
liquid
autoignition temp.
973 °F
expl. lim.
16 %
Looking for similar products? Visit Product Comparison Guide
General description
Its other applications include its use as a mobile phase additive and as an extraction solvent in liquid-liquid extraction (LLC), solid-phase extraction (SPE) and microextraction for chromatographic applications, etc.[1]
Application
- As an extraction solvent for the quantification of pesticide analytes in foodstuffs[2][3] and tea,[4] industrial dyes in juice and wine[5] by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).
- As an organic modifier in the determination of bisphenol A-diglycidyl ether, bisphenol F-diglycidyl ether and their derivatives in canned food and beverages by fast LC–MS/MS.[6]
Legal Information
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point(F)
35.6 °F - closed cup
Flash Point(C)
2.0 °C - closed cup
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Articles
Optimized separation of Oligo Standard 6, an internally created HPLC-UV system suitability mix, on Chromolith® RP-18e columns with an evaluation of the effect of flow rates up to 3 mL/min and ion-pairing reagent, TEAA, on the separation.
Optimized separation of Oligo Standard 6, an internally created HPLC-UV system suitability mix, on Chromolith® RP-18e columns with an evaluation of the effect of flow rates up to 3 mL/min and ion-pairing reagent, TEAA, on the separation.
Optimized separation of Oligo Standard 6, an internally created HPLC-UV system suitability mix, on Chromolith® RP-18e columns with an evaluation of the effect of flow rates up to 3 mL/min and ion-pairing reagent, TEAA, on the separation.
Optimized separation of Oligo Standard 6, an internally created HPLC-UV system suitability mix, on Chromolith® RP-18e columns with an evaluation of the effect of flow rates up to 3 mL/min and ion-pairing reagent, TEAA, on the separation.
Protocols
Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.
Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.
Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.
Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service