Skip to Content
MilliporeSigma

96351

Pullulan Standard Set Mp ~350 - 700′000

set of analytical standards, suitable for gel permeation chromatography (GPC)

Synonym(s):

Pullulan Standard Set

Sign In to View Organizational & Contract Pricing.

Select a Size

1 KIT

$3,936.00

$3,936.00

List Price$4,920.00Save 20%

Please contact Customer Service for Availability

Request a Bulk Order

About This Item

CAS Number:
MDL number:
UNSPSC Code:
41116107
EC Number:
232-945-1
NACRES:
NA.24
E Number:
E1204

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Pullulan Standard Set Mp ~350 - 700′000, set of analytical standards, suitable for gel permeation chromatography (GPC)

grade

analytical standard

shelf life

limited shelf life, expiry date on the label

analyte chemical class(es)

oligosaccharides

technique(s)

gel permeation chromatography (GPC): suitable

application(s)

cleaning products
cosmetics
food and beverages
personal care

format

neat

storage temp.

2-8°C

Quality Level

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
438074705353168
technique(s)

gel permeation chromatography (GPC): suitable

technique(s)

gel permeation chromatography (GPC): suitable

technique(s)

gel permeation chromatography (GPC): suitable

technique(s)

gel permeation chromatography (GPC): suitable

application(s)

cleaning products
cosmetics
food and beverages
personal care

application(s)

cleaning products
cosmetics
food and beverages
personal care

application(s)

cleaning products
cosmetics
food and beverages
personal care

application(s)

cleaning products
cosmetics
food and beverages
personal care

format

neat

format

neat

format

neat

format

neat

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

100

grade

analytical standard, for GPC

grade

certified reference material, for GPC

grade

certified reference material, for GPC

grade

certified reference material, for GPC

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

Application

The set of analytical standards can also be used as follows:
  • Calibration of the polymer-based column in the estimation of molecular weight of the polysaccharide fractions obtained from seaweeds— S. latissima and M. stellatus, by a high-performance size exclusion chromatography (HPSEC) method
  • Measurement of molecular masses of oligomeric cellulose by size exclusion chromatography in combination with multi-angle laser light scattering (MALLS) detection
  • To calibrate the SEC column in the determination of molecular size distribution of microalgal native glycogen
  • Quantitative analysis of membrane formation process of alginate–chitosan microcapsules using gel permeation chromatography(GPC).[1]

General description

Pullulan is a linear glucan polysaccharide made up of α-1,4-maltotriose repeating units. It is produced by yeast-like fungus Aureobasidium pullulans from starch and has α-1,6 linkages between two maltotriose units.[2]

Other Notes

Kit with carefully selected reference materials to calibrate GPC/SEC/GFC systems. The kit contains standards of the same type, but with different molar masses, a certificate of analysis (CoA) for each standard and an example calibration curve with analytical conditions.
The standards need to be weighed before use. Suitable for calibrations in aqueous solutions and DMSO.
Kit contains 10 different pullulan standards, each 100 mg, with Mp ranging from ~350 to ~700,000.

Storage Class

10 - Combustible liquids

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Quantitative characterization of membrane formation process of alginate?chitosan microcapsules by GPC
Yu W, et al.
Journal of Membrane Science, 346, 296-301 (2010)
Rahul Garhwal et al.
Investigative ophthalmology & visual science, 53(3), 1341-1352 (2012-01-24)
To formulate conventional contact lenses that incorporate nanosphere-encapsulated antibiotic and demonstrate that the lenses provide for sustained antibacterial activity. A copolymer composed of pullulan and polycaprolactone (PCL) was used to synthesize core-shell nanospheres that encapsulated ciprofloxacin. Bactericidal activity of the
Xiaojun Tao et al.
PloS one, 7(11), e49304-e49304 (2012-11-21)
Nanoparticle (NP) compositions such as hydrophobicity and surface charge are vital to determine the presence and amount of human serum albumin (HSA) binding. The HSA binding influences drug release, biocompatibility, biodistribution, and intercellular trafficking of nanoparticles (NPs). Here, we prepared
Pei-Hong Miao et al.
Die Pharmazie, 67(3), 229-232 (2012-04-26)
Current efforts had been made to undertake a three-dimensional (3-D) reverse transfection of bone marrow-derived mesenchymal stem cells (BM-MSCs) in PLGA scaffolds. As a kind of multipotent stem cells, BM-MSCs show great potential and tremendous capacity in the gene transfection
Marieta Constantin et al.
Carbohydrate polymers, 91(1), 74-84 (2012-10-10)
Pullulan-graft-poly(3-acrylamidopropyl trimethylammonium chloride) (P-g-pAPTAC) microspheres were prepared by suspension cross-linking of the pullulan previously grafted with cationic moieties. Adsorption of Azocarmine B by the P-g-pAPTAC microspheres was used as a model to demonstrate the removal of anionic dyes from aqueous

Related Content

Dextrans are polysaccharides with molecular weights ≥1,000 Dalton, featuring a linear backbone of α-linked d-glucopyranosyl repeating units.

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What is specification for GPC pullulan standards. Pullulan standard with Mp 22000Da supplied in different lot can vary how much % from 22000Da

    1 answer
    1. This product is intended for use as a calibration standard for GPC/SEC/GFC systems. While there is not specification for the Mp values, these are reported on the lot specific Certificate of Analysis. The lowest value reported for the Mp 220000Da is 19.4000Da. Please see the link below to review a sample or lot specific Certificate:

      https://www.sigmaaldrich.com/product/sial/96351#product-documentation

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service