Accéder au contenu
Merck

Screening for petrochemical contamination in seafood by headspace solid-phase microextraction gas chromatography-mass spectrometry.

Analytical and bioanalytical chemistry (2015-03-23)
F Aladar Bencsath, Ronald A Benner, Ann Abraham, Yuesong Wang, Kathleen R El Said, Edward L E Jester, Steven M Plakas
RÉSUMÉ

A headspace solid-phase microextraction gas chromatography-mass spectrometry (SPME GC-MS) method is described, to screen seafood for volatile organic compounds (VOCs) associated with petrochemical taint. VOCs are extracted from the headspace of heated sample homogenates by adsorption onto a SPME fiber and desorbed for analysis by GC-MS. Targeted compounds are determined semi-quantitatively using representative calibration standards for the various classes (alkanes, alkylbenzenes, indanes/tetralins, and naphthalenes) of VOCs analyzed. Sample preparation is minimal, and the analyses are rapid and automated with a capacity of 50 samples per day. The method was optimized in terms of headspace temperature, sample heating time, extraction time, and desorption time using oyster samples fortified with target compounds. Calibrations for hydrocarbon components were linear in the range of 8.3-167 ng/g; the limit of detection ranged between 0.05 and 0.21 ng/g, and the limit of quantitation between 0.16 and 0.69 ng/g. Good precision (RSD < 10 % at 16.7 ng/g for individual VOCs) and accuracy (recovery range 89-118 % at 25 ng/g) were obtained in oyster, crab, shrimp, and finfish matrices. The trueness of the method was demonstrated by quantifying VOCs at 1-2-ppb levels in oyster fortified with certified reference material NIST SRM 1491a. Following single laboratory validation, the method was employed for the determination of VOCs in seafood exposed to oil contaminated seawater and for the determination of background VOC levels in seafood species from the Gulf of Mexico and local food stores. The method as described can be used to supplement human sensory testing for petrochemical taint in seafood.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Triton X-100, laboratory grade
Sigma-Aldrich
Naphthalene, 99%
Sigma-Aldrich
Tetradecane, ≥99%
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Sigma-Aldrich
Tetradecane, olefin free, ≥99.0% (GC)
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Sigma-Aldrich
1-Methylnaphthalene, 95%
Sigma-Aldrich
Mesitylene, 98%
Sigma-Aldrich
Tridecane, ≥99%
Sigma-Aldrich
p-Xylene, anhydrous, ≥99%
Sigma-Aldrich
Naphthalène-d8, 99 atom % D, ≥98% (CP)
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Sigma-Aldrich
Naphthalene, suitable for scintillation, ≥99%
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Sigma-Aldrich
1,2,3,4-Tetrahydronaphthalene, anhydrous, 99%
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPME StableFlex fiber assortment kit, for use with manual holder
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Sigma-Aldrich
Indan, 95%
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Sigma-Aldrich
2,6-Dimethylnaphthalene, 99%
Sigma-Aldrich
1-Methylnaphthalene, ≥95%
Supelco
Assortiment de fibres SPME 4, for use with manual holder, size 24 ga
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga