  • Headspace sorptive extraction (HSSE), stir bar sorptive extraction (SBSE), and solid phase microextraction (SPME) applied to the analysis of roasted Arabica coffee and coffee brew.

Headspace sorptive extraction (HSSE), stir bar sorptive extraction (SBSE), and solid phase microextraction (SPME) applied to the analysis of roasted Arabica coffee and coffee brew.

Journal of agricultural and food chemistry (2002-01-24)
Carlo Bicchi, Cristina Iori, Patrizia Rubiolo, Pat Sandra
ABSTRACT

Headspace sorptive extraction (HSSE) and stir bar sorptive extraction (SBSE), two recently introduced solventless enrichment techniques, have been applied to the analysis of the headspace of Arabica roasted coffee and of the headspace of the brew and of the brew itself. In both HSSE and SBSE enrichment is performed on a thick film of poly(dimethylsiloxane) (PDMS) coated onto a magnet incorporated in a glass jacket. Sampling is done by placing the PDMS stir bar in the headspace (gas phase extraction or HSSE) or by immersing it in the liquid (liquid phase extraction or SBSE). The stir bar is then thermally desorbed on-line with capillary GC-MS. The performance of HSSE and SBSE have been compared through the determination of the recoveries and relative abundances of 16 components of the coffee volatile fraction to classical static headspace (S-HS) and to headspace and in-sample solid phase microextraction (HS-SPME and IS-SPME, respectively) applying the fibers PDMS 100 microm, Carbowax/divinylbenzene 65 microm (CW/DVB), Carboxen/PDMS 75 microm(CAR/PDMS), polyacrylate 85 microm(PA), PDMS/divinylbenzene 65 microm(PDMS/DVB), and Carboxen/divinylbenzene/PDMS 50-30 microm(CAR/PDMS/DVB). In all cases, HSSE and SBSE gave higher recoveries, and this is entirely due to the high amount of PDMS applied.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Carboxen®-1006 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm