Skip to Content
Merck
  • Ageing and retail display time in raw beef odour according to the degree of lipid oxidation.

Ageing and retail display time in raw beef odour according to the degree of lipid oxidation.

Food chemistry (2017-10-19)
Virginia C Resconi, Mónica Bueno, Ana Escudero, Danielle Magalhaes, Vicente Ferreira, M Mar Campo
ABSTRACT

This study aims to assess the changes in beef aroma over time when steaks from pre-aged knuckles are stored in retail display under high oxygen conditions for 15 or 22days in vacuum conditions. Odorous volatile compounds were analysed by solid-phase microextraction/gas chromatography-mass spectrometry. Results were grouped as low, medium and high oxidative groups according to thiobarbituric acid reactive substances values after 9days of display. The intensity of off-odours in the raw meat increased with ageing and display time and oxidative groups. Based on correlations between the variables and regressions of the compounds through display, eight compounds were proposed as odour shelf-life markers. Among them, five were most sensitive and precise in all oxidative groups: 1-hexanol in meat aged for 15days, ethyl- octanoate and 2-pentylfuran in meat aged for 22days, and pentanoic and hexanoic acids in the two studied ageing times.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
trans-2-Nonenal, 97%
Sigma-Aldrich
1,1,3,3-Tetramethoxypropane, 99%
Sigma-Aldrich
trans-2-Heptenal, ≥95%, stabilized, FG
Sigma-Aldrich
trans-2-Octenal, technical grade, 94%
Sigma-Aldrich
Hexanal, 98%
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler, fiber L 1 cm, pk of 3
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex fiber, for use with autosampler, fiber L 2 cm, pk of 3
Supelco
SPME Sampling Stand, for use with 4 mL vials
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler, fiber L 2 cm, pk of 3
Sigma-Aldrich
2-Pentylfuran, ≥98%, FG
Sigma-Aldrich
Phenylacetaldehyde, ≥95%, FCC, FG
Sigma-Aldrich
Ethyl hexanoate, ≥99%
Sigma-Aldrich
Dipropylene glycol, 99%, mixture of isomers