Skip to Content
Merck
  • Multivariate analysis of mainstream tobacco smoke particulate phase by headspace solid-phase micro extraction coupled with comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry.

Multivariate analysis of mainstream tobacco smoke particulate phase by headspace solid-phase micro extraction coupled with comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry.

Journal of chromatography. A (2014-12-03)
Michał Brokl, Louise Bishop, Christopher G Wright, Chuan Liu, Kevin McAdam, Jean-François Focant
ABSTRACT

A method involving headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography (GC×GC) coupled to time-of-flight mass spectrometry (TOFMS) was developed and applied to evaluate profiles of volatile compounds present in mainstream tobacco smoke particulate matter trapped on glass fiber filters. Six SPME fibers were tested for the extraction capacities toward selected compounds, showing the best results for the polyacrylate fiber. The optimization of the extraction conditions was carried out using multivariate response surface methodology. Two cigarette types differing in a filter design were analyzed using optimized conditions. A template was built in order to generate comprehensive chemical information, which conceded obtaining consistent information across 24 chromatograms. Principal component analysis (PCA) allowed a clear differentiation of the studied cigarette types. Fisher ratio analysis allowed identification of compounds responsible for the chemical differences between the cigarette samples. Of the selected 143 most important ones, 134 analytes were reduced by the active carbon filter, while for nine, classical cellulose acetate filter was more efficient.

MATERIALS
Product Number
Brand
Product Description

Supelco
Melting point standard 79-81°C, analytical standard
Sigma-Aldrich
Pyrvinium pamoate salt hydrate, ≥98% (HPLC)
Supelco
Pyridine, analytical standard
Sigma-Aldrich
Ethylbenzene, anhydrous, 99.8%
Sigma-Aldrich
Pyridine, anhydrous, 99.8%
Sigma-Aldrich
Phenol, unstabilized, ReagentPlus®, ≥99%
Sigma-Aldrich
Phenol, ACS reagent, ≥99.0%
Supelco
Ethylbenzene, analytical standard
Sigma-Aldrich
Phenol, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.5-100.5% (GC)
Sigma-Aldrich
Phenol, puriss., ≥99.5% (GC), meets analytical specification of Ph. Eur., BP, USP, crystalline (detached)
Sigma-Aldrich
Phenol, ≥96.0% (calc. on dry substance, T)
Sigma-Aldrich
Phenol, unstabilized, purified by redistillation, ≥99%
Sigma-Aldrich
Quinoline, reagent grade, 98%
Sigma-Aldrich
Perchloric acid, 70%, 99.999% trace metals basis
Sigma-Aldrich
Phenol, ≥99%
Sigma-Aldrich
Phenol, BioUltra, for molecular biology, TE-saturated, ~73% (T)
Supelco
Phenol solution, 100 μg/mL in acetonitrile, PESTANAL®, analytical standard
Sigma-Aldrich
Phenol, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Pyridine, ≥99%
Sigma-Aldrich
Phenol, puriss. p.a., ACS reagent, reag. Ph. Eur., 99.0-100.5%
Sigma-Aldrich
Phenol, BioXtra, ≥99.5% (GC)
Sigma-Aldrich
Liquified Phenol, ≥89.0%
Sigma-Aldrich
Phenol, for molecular biology
Sigma-Aldrich
Phenol solution, BioReagent, Saturated with 0.01 M citrate buffer, pH 4.3 ± 0.2, for molecular biology
Sigma-Aldrich
Phenol solution, Equilibrated with 10 mM Tris HCl, pH 8.0, 1 mM EDTA, BioReagent, for molecular biology
Sigma-Aldrich
DL-p-Chloroamphetamine hydrochloride, ≥94% (HPLC)
Supelco
Phenol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Phenol, PESTANAL®, analytical standard
Sigma-Aldrich
Perchloric acid, ACS reagent, 70%
Sigma-Aldrich
Pyridine, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99.5% (GC)