Skip to Content
MilliporeSigma
  • Homogeneous liquid-liquid extraction of neodymium(III) by choline hexafluoroacetylacetonate in the ionic liquid choline bis(trifluoromethylsulfonyl)imide.

Homogeneous liquid-liquid extraction of neodymium(III) by choline hexafluoroacetylacetonate in the ionic liquid choline bis(trifluoromethylsulfonyl)imide.

Dalton transactions (Cambridge, England : 2003) (2014-06-19)
Bieke Onghena, Jeroen Jacobs, Luc Van Meervelt, Koen Binnemans
ABSTRACT

The ionic liquid choline bis(trifluoromethylsulfonyl)imide, [Chol][Tf2N], was used for the extraction of neodymium(III), in combination with choline hexafluoroacetylacetonate, [Chol][hfac], as the extractant. The binary mixture of [Chol][Tf2N] and water shows temperature-dependent phase behavior, with an upper critical solution temperature of 72 °C. A novel extraction technique, homogeneous liquid-liquid extraction (HLLE), was applied to this solvent system. HLLE is based on the use of thermomorphic solvent mixtures and has the advantage of forming a homogeneous phase during mixing. Extraction is not kinetically hindered by an interface and the extraction equilibrium is reached faster than in the case of heterogeneous mixing in conventional solvent extraction. Several extraction parameters were studied for the extraction of neodymium(III) with [Chol][hfac]: temperature, pH, extractant concentration and loading of the ionic liquid phase. A speciation study was performed to determine the stoichiometry of the extracted neodymium(III) complex and a plausible extraction mechanism is proposed. Neodymium is extracted as a tetrakis hexafluoroacetylacetonate complex with one choline cation as counter ion. The crystal structure of the extracted complex showed the presence of a coordination bond between the choline counter ion and the neodymium(III) center, resulting in a coordination number of nine. The stripping of the loaded neodymium and the influence of acid and extractant concentrations on the phase behavior of the [Chol][Tf2N]-H2O system were investigated.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
2-Propanol, JIS special grade, ≥99.5%
Sigma-Aldrich
Ethanol, ≥99.5%, SAJ super special grade
Sigma-Aldrich
Ethanol, JIS 1000, ≥99.5%, for residue analysis
Sigma-Aldrich
Nitric acid, 1 M
Sigma-Aldrich
Ethanol, ≥99.5%
Sigma-Aldrich
Nitric acid, SAJ first grade, 65.0-66.0%, density: 1.40
Sigma-Aldrich
Nitric acid, 0.1 M
Sigma-Aldrich
Ethanol, JIS 300, ≥99.5%, for residue analysis
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for absorption spectrum analysis
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for HPLC
Sigma-Aldrich
2-Propanol, SAJ first grade, ≥99.0%
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for fluorescence
Sigma-Aldrich
Nitric acid, ACS reagent, ≥90.0%
Sigma-Aldrich
Dysprosium, ingot, 99.9% trace rare earth metals basis
Sigma-Aldrich
2-Propanol, ACS reagent, ≥99.5%
Sigma-Aldrich
Dysprosium, chips, 99.9% trace rare earth metals basis
Sigma-Aldrich
2-Propanol, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%, poly coated bottles
Sigma-Aldrich
2-Propanol, 99.5%, HPLC grade
Supelco
Ethanol standards 10% (v/v), 10 % (v/v) in H2O, analytical standard
Sigma-Aldrich
2-Propanol, suitable for HPLC
Sigma-Aldrich
2-Propanol, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
2-Propanol, suitable for HPLC, 99.9%
Sigma-Aldrich
2-Propanol, anhydrous, 99.5%
Supelco
2-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2-Propanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
2-Propanol, ACS reagent, ≥99.5%
Sigma-Aldrich
2-Propanol, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
2-Propanol, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
2-Propanol, for molecular biology, BioReagent, ≥99.5%