Recommended Products
form
powder or crystals
Quality Level
composition
Dye content, ≥75%
mp
>300 °C (lit.)
λmax
496 nm
application(s)
diagnostic assay manufacturing
hematology
histology
storage temp.
room temp
SMILES string
Cl.Nc1ccc2c(OC3=CC(=N)C=CC3=C2c4ccccc4C(O)=O)c1
InChI
1S/C20H14N2O3.ClH/c21-11-5-7-15-17(9-11)25-18-10-12(22)6-8-16(18)19(15)13-3-1-2-4-14(13)20(23)24;/h1-10,21H,22H2,(H,23,24);1H
InChI key
JNGRENQDBKMCCR-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
General description
Rhodamine 110 chloride (R110) is a laser grade dye.
Application
Rhodamine 110 chloride has been used for the synthesis of the rhodamine 110 octadecyl ester (R110C18).
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Personal Protective Equipment
dust mask type N95 (US), Eyeshields, Gloves
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
PloS one, 7(3), e33253-e33253 (2012-04-04)
Fluorescent tracer dyes represent an important class of sub-cellular probes and allow the examination of cellular processes in real-time with minimal impact upon these processes. Such tracer dyes are becoming increasingly used for the examination of membrane transport processes, as
The journal of physical chemistry. B, 114(11), 4035-4046 (2010-03-04)
Triplet, photo-oxidized and other photoinduced, long-lived states of fluorophores are sensitive to the local environment and thus attractive for microenvironmental imaging purposes. In this work, we introduce an approach where these states are monitored in a total internal reflection (TIR)
Electrophoresis, 32(24), 3499-3509 (2011-12-20)
We describe a highly sensitive CE with laser-induced fluorescence (LIF) detection for the analysis of N-linked oligosaccharides in glycoproteins using rhodamine 110 as a fluorescence derivatization reagent. One CE separation is performed using a fused-silica capillary and neutral pH buffer
Analytical chemistry, 84(5), 2380-2387 (2012-02-14)
By site directed mutagenesis, we have produced recombinant mutants of human and mouse prethrombin-2 which are able to convert themselves autocatalytically into α-thrombin. We also have created a new method to amplify the signal of bioanalytical assays based on the
Analytica chimica acta, 651(1), 85-90 (2009-09-08)
The ability to quickly measure flow parameters in microfluidic devices is critical for micro total analysis system (microTAS) applications. Macrofluidic methods to assess flow suffer from limitations that have made conventional methods unsuitable for the flow behavior profiling. Single molecule
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service