Saltar al contenido
MilliporeSigma

Determination of Urinary PAH Metabolites Using DLLME Hyphenated to Injector Port Silylation and GC-MS-MS.

Journal of analytical toxicology (2015-04-08)
Manoj Kumar Gupta, Rajeev Jain, Pratibha Singh, Ratnasekhar Ch, Mohana Krishna Reddy Mudiam
RESUMEN

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental pollutants and well-known carcinogens. Hydroxy derivatives of PAH are considered as biomarkers of PAH exposure, and there is a need to measure these metabolites at low concentrations. So, a precise and eco-friendly analytical method has been developed for rapid determination of PAH metabolites. For the first time, a new analytical method based on coupling of dispersive liquid-liquid microextraction (DLLME) with auto-injector port silylation (auto-IPS) followed by gas chromatography-tandem mass spectrometry (GC-MS-MS) analysis is reported for the analysis of seven urinary PAH metabolites. Factors affecting DLLME and IPS, such as type and volume of extraction and disperser solvent, pH, ionic strength, injector port temperature, volume of N,O-bis(trimethylsilyl)trifluoroacetamide and type of solvent were investigated. Under optimized conditions, the limit of detection and limit of quantification were found to be in the range of 1-9 and 3-29 ng/mL, respectively. Satisfactory recoveries of metabolites in urine samples in the range of 87-95% were found. The developed method has been successfully applied for the determination of PAH metabolites in urine samples of exposed workers. DLLME-auto-IPS-GC-MS-MS method is time, labor, solvent and reagent saving, which can be routinely used for the analysis of urinary PAH metabolites.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Supelco
N,O-bis(trimetilsilil)trifluoroacetamida con trimetilclorosilano, with 1% trimethylchlorosilane, for GC derivatization, LiChropur
Sigma-Aldrich
Clorotrimetilsilano, ≥98.0% (GC)
Sigma-Aldrich
Clorotrimetilsilano, purified by redistillation, ≥99%
Sigma-Aldrich
N,O-bis(trimetilsilil)trifluoroacetamida, ≥99%
Sigma-Aldrich
Metanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Diclorometano, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Alcohol etílico puro, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Metanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Alcohol etílico puro, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Cloroformo, JIS special grade, ≥99.0%
Sigma-Aldrich
Acetato de etilo
Sigma-Aldrich
Acetato de etilo, ≥99%, FCC, FG
Sigma-Aldrich
Acetato de etilo, anhydrous, 99.8%
Sigma-Aldrich
Hexano, JIS special grade, ≥96.0%
Sigma-Aldrich
Hexano, anhydrous, 95%
Supelco
Ethanol solution, 10 % (v/v) in H2O, analytical standard
Sigma-Aldrich
Acetonitrilo, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Chlorobenzene, anhydrous, 99.8%
Sigma-Aldrich
Acetato de etilo, natural, ≥99%, FCC, FG
Supelco
Acetonitrilo, HPLC grade, ≥99.93%
Sigma-Aldrich
Metanol, suitable for HPLC
Sigma-Aldrich
Etanol, ≥99.5%, suitable for HPLC
Sigma-Aldrich
Acetonitrilo, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Cloroformo, ≥99%, PCR Reagent, contains amylenes as stabilizer
Sigma-Aldrich
Metanol, SAJ special grade
Sigma-Aldrich
Etanol, JIS special grade, 94.8-95.8%
Sigma-Aldrich
Cloroformo, anhydrous, ≥99%, contains 0.5-1.0% ethanol as stabilizer
Supelco
Dichloromethane solution, contains 10 % (v/v) methanol