  • Ultra performance liquid chromatography-tandem mass spectrometry for the determination of amicarthiazol residues in soil and water samples.

Ultra performance liquid chromatography-tandem mass spectrometry for the determination of amicarthiazol residues in soil and water samples.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-12-03)
Wen-jun Gui, Jie Tian, Chun-xia Tian, Shu-ying Li, You-ning Ma, Guo-nian Zhu
RESUMEN

A reliable and rapid method has been optimized to determine the residue of amicarthiazol in soil and environmental water samples. After extraction and evaporation, the extraction was carried out with solid phase extraction (SPE) cleanup using HLB cartridge (only soil samples) and for the quantitative determination by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The resulting residues of amicarthiazol were analyzed by a gradient separation performed on a UPLC system with a C18 column, methanol and water containing 0.1% (v v(-1)) formic acid as the mobile phase in the mode of electrospray positive ionization (ESI(+)) and multiple reaction monitoring (MRM). Results showed that the recoveries for spiked samples were 74.4-97.1% and 72.1-109.9% for soil and water, respectively, with the relative standard deviation (RSD) less than 10.2% when fortified at 10, 100 and 1000μgL(-1). The limits of detection (LODs) and the limits of quantification (LOQs) for matrix matched standards ranged from 0.073-0.425μgL(-1) and 0.243-1.42μgL(-1). The intra-day precision (n=5) and the inter-day precision over 10 days (n=10) for the amicarthiazol in soils and water samples spiked at 100μgL(-1) was 7.9% and 15.9%, respectively. Results indicated that the developed method could be a helpful tool for the controlling and monitoring of the risks posed by amicarthiazol to human health and environment safety.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Sigma-Aldrich
Metanol, Absolute - Acetone free
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Acetonitrilo, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanol, JIS special grade, ≥99.8%
USP
Metanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrilo, biotech. grade, ≥99.93%
Supelco
Metanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Metanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Supelco
Metanol, analytical standard
Sigma-Aldrich
Acetonitrilo solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrilo, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrilo solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Metanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)