Saltar al contenido
MilliporeSigma

A new apparatus for real-time assessment of the particle size distribution of disintegrating tablets.

Journal of pharmaceutical sciences (2014-09-17)
Julian Quodbach, Peter Kleinebudde
RESUMEN

The aim of this study is the introduction of a novel apparatus that is capable of continuously measuring the particle size reduction of disintegrating tablets and analysis of the obtained results. The apparatus is constructed such that no particles pass directly through the pumping system. Thereby, the overall energy input into the particle suspension is reduced, and continuous measurement is possible without rapid destruction of the generated particles. The detected particle sizes at the beginning and at the end of the measurement differ greatly, depending on the applied disintegrant. The median particle sizes at the end of the measurement vary between 621.5 and 178.0 μm for different disintegrants. It is demonstrated that the particle size reduction follows an exponential function and that the fit parameters can be used to describe the disintegration behavior. A strong correlation between the median particle size of crospovidone disintegrants and generated particle size of the tablets is observed. This could be due to a more homogeneous distribution of the disintegrant particles in the tablets. Similar trends are observed for sodium starch glycolate and croscarmellose sodium. The new apparatus provides an innovative method to describe disintegrant effectiveness and efficiency.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Óxido de alúmina, activated, basic, Brockmann I
Sigma-Aldrich
Óxido de alúmina, activated, neutral, Brockmann I
Sigma-Aldrich
Óxido de alúmina, powder, 99.99% trace metals basis
Sigma-Aldrich
Óxido de alúmina, activated, acidic, Brockmann I
Sigma-Aldrich
Óxido de alúmina, powder, primarily α phase, ≤10 μm avg. part. size, 99.5% trace metals basis
Sigma-Aldrich
Óxido de alúmina, nanopowder, <50 nm particle size (TEM)
Sigma-Aldrich
Aluminum oxide, nanoparticles, <50 nm particle size (DLS), 20 wt. % in isopropanol
Sigma-Aldrich
Magnesium stearate, technical grade
Sigma-Aldrich
Óxido de alúmina, Corundum, α-phase, -100 mesh
Sigma-Aldrich
Óxido de alúmina, pellets, 3 mm
Sigma-Aldrich
Óxido de alúmina, fused, powder, primarily α-phase, -325 mesh
Sigma-Aldrich
Óxido de alúmina, nanopowder, 13 nm primary particle size (TEM), 99.8% trace metals basis
Sigma-Aldrich
Óxido de alúmina, 99.997% trace metals basis
Sigma-Aldrich
Óxido de alúmina, Type WN-6, Neutral, Activity Grade Super I
Sigma-Aldrich
Óxido de alúmina, pore size 58 Å, ~150 mesh
Sigma-Aldrich
Aluminum oxide, nanoparticles, 30-60 nm particle size (TEM), 20 wt. % in H2O
Sigma-Aldrich
Óxido de alúmina, fused, powder, primarily α-phase, 100-200 mesh
Sigma-Aldrich
Óxido de alúmina, single crystal substrate, <0001>
Sigma-Aldrich
Óxido de alúmina, nanowires, diam. × L 2-6 nm × 200-400 nm
Sigma-Aldrich
Aluminum oxide, mesostructured, MSU-X (wormhole), average pore size 3.8 nm
Sigma-Aldrich
Óxido de alúmina, activated, neutral, Brockmann I, free-flowing, Redi-Dri
Sigma-Aldrich
Óxido de alúmina, activated, acidic, Brockmann I, free-flowing, Redi-Dri
Supelco
Óxido de alúmina, activated, neutral, Brockmann Activity I
Sigma-Aldrich
Magnesium stearate, puriss., meets analytical specification of Ph. Eur., BP, ≥90% stearic and palmitic acid basis, ≥40% stearic acid basis (GC), 4.0-5.0% Mg basis (calc on dry sub.)
Sigma-Aldrich
Óxido de alúmina, CP
Supelco
Óxido de alúmina, for the determination of hydrocarbons