Saltar al contenido
MilliporeSigma

Treatment of steam-assisted gravity drainage water using low coagulant dose and Fenton oxidation.

Environmental technology (2014-06-25)
Ahmad Al-As'ad, Maen M Husein
RESUMEN

The use of coagulation and Fenton oxidation was studied for total organic carbon (TOC) and silica removal from steam-assisted gravity drainage (SAGD) water at 800C and two different concentrations replicating the stream feeding the warm lime softening unit having 675 mg/L TOC and 350 mg/L silica and the blowdown of the once through steam generator having 3700mg/L TOC and 2585 mg/L silica. Coagulation was carried out by the addition of FeCl3, Al(NO3)3 or Ca(NO3)2. The results showed that Fe(III) salt outperformed Al(III) and Ca(II) salts. A two-stage addition of 2.5 g FeCl3 per g TOC intermediated by a filtration unit resulted in approximately 72% TOC removal and more than 80% silica removal while maintaining low solid waste. Comparing results pertaining to coagulant concentration and final pH, it can be easily concluded that silica removal is governed by the resultant pH, whereas TOC removal was accomplished through surface neutralization and localized enmeshment coagulation. Fenton oxidation is proposed to further treat the filtrate obtained from the second stage Fe(III) coagulation. An additional 10% TOC removal could be achieved; at seven times lower H202 dose in the presence of Fe2+ or Fe0 reagent. Moreover, the advanced Fenton process resulted in high silica removal as a result of adsorption onto Fe(OH)3 precipitate, which formed at the equilibrium pH of the system.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Peróxido de hidrógeno solution, contains inhibitor, 30 wt. % in H2O, ACS reagent
Sigma-Aldrich
Peróxido de hidrógeno solution, 30 % (w/w) in H2O, contains stabilizer
Sigma-Aldrich
Peróxido de hidrógeno solution, 50 wt. % in H2O, stabilized
Sigma-Aldrich
Iron, ≥99%, reduced, powder (fine)
Sigma-Aldrich
Peróxido de hidrógeno solution, 30% (w/w), puriss. p.a., reag. ISO, reag. Ph. Eur.
Sigma-Aldrich
LUDOX® HS-40 colloidal silica, 40 wt. % suspension in H2O
Sigma-Aldrich
Sílice, nanopowder, 10-20 nm particle size (BET), 99.5% trace metals basis
Sigma-Aldrich
Peróxido de hidrógeno solution, contains ~200 ppm acetanilide as stabilizer, 3 wt. % in H2O
Sigma-Aldrich
Peróxido de hidrógeno solution, contains inhibitor, 35 wt. % in H2O
Sigma-Aldrich
LUDOX® AS-40 colloidal silica, 40 wt. % suspension in H2O
Sigma-Aldrich
Peróxido de hidrógeno solution, purum p.a., ≥35% (RT)
Sigma-Aldrich
Sílice, nanoparticles, mesoporous, 200 nm particle size, pore size 4 nm
Sigma-Aldrich
Sílice, nanopowder (spherical, porous), 5-20 nm particle size (TEM), 99.5% trace metals basis
Sigma-Aldrich
LUDOX® TM-50 colloidal silica, 50 wt. % suspension in H2O
Sigma-Aldrich
Carbonyl iron, ≥97% Fe basis
Sigma-Aldrich
Sílice, nanopowder, 99.8% trace metals basis
Millipore
Peróxido de hidrógeno solution, 3%, suitable for microbiology
Sigma-Aldrich
Sílice, MCM-41 type (hexagonal)
Sigma-Aldrich
Iron, puriss. p.a., carbonyl-Iron powder, low in magnesium and manganese compounds, ≥99.5% (RT)
Sigma-Aldrich
Sílice
Sigma-Aldrich
Iron, granular, 10-40 mesh, >99.99% trace metals basis
Sigma-Aldrich
Iron, powder, −325 mesh, 97%
Sigma-Aldrich
LUDOX® SM colloidal silica, 30 wt. % suspension in H2O
Sigma-Aldrich
Iron, powder, <10 μm, ≥99.9% trace metals basis
Sigma-Aldrich
LUDOX® AM colloidal silica, 30 wt. % suspension in H2O
Sigma-Aldrich
LUDOX® HS-30 colloidal silica, 30 wt. % suspension in H2O
Sigma-Aldrich
LUDOX® TM-40 colloidal silica, 40 wt. % suspension in H2O
Supelco
Peróxido de hidrógeno solution, ≥30%, for trace analysis
Sigma-Aldrich
Peróxido de hidrógeno solution, contains inhibitor, 30 wt. % in H2O, meets USP testing specifications
Sigma-Aldrich
Peróxido de hidrógeno solution, SAJ first grade, ≥30.0%