Saltar al contenido
MilliporeSigma
  • Effects of chronic waterborne nickel exposure on growth, ion homeostasis, acid-base balance, and nickel uptake in the freshwater pulmonate snail, Lymnaea stagnalis.

Effects of chronic waterborne nickel exposure on growth, ion homeostasis, acid-base balance, and nickel uptake in the freshwater pulmonate snail, Lymnaea stagnalis.

Aquatic toxicology (Amsterdam, Netherlands) (2014-03-19)
Som Niyogi, Kevin V Brix, Martin Grosell
RESUMEN

The freshwater pulmonate snail, Lymnaea stagnalis, is the most sensitive aquatic organism tested to date for Ni. We undertook a series of experiments to investigate the underlying mechanism(s) for this observed hypersensitivity. Consistent with previous experiments, juvenile snail growth in a 21-day exposure was reduced by 48% relative to the control when exposed to 1.3 μg l(-1) Ni (EC20 less than the lowest concentration tested). Ca(2+) homeostasis was significantly disrupted by Ni exposure as demonstrated by reductions in net Ca(2+) uptake, and reductions in Ca(2+) concentrations in the hemolymph and soft tissues. We also observed reduced soft tissue [Mg(2+)]. Snails underwent a significant alkalosis with hemolymph pH increasing from 8.1 to 8.3 and hemolymph TCO2 increasing from 19 to 22 mM in control versus Ni-exposed snails, respectively. Unlike in previous studies with Co and Pb, snail feeding rates were found to be unaffected by Ni at the end of the exposure. Snails accumulated Ni in the soft tissue in a concentration-dependent manner, and Ni uptake experiments with (63)Ni revealed a biphasic uptake profile - a saturable high affinity component at low exposure concentrations (36-189 nM) and a linear component at the high exposure concentrations (189-1,897 nM). The high affinity transport system had an apparent Km of 89 nM Ni(2+) and Vmax of 2.4 nmol g(-1)h(-1). This equates to a logK of 7.1, significantly higher than logK's (2.6-5.2) for any other aquatic organisms evaluated to date, which will have implications for Biotic Ligand Model development. Finally, pharmacological inhibitors that block Ca(2+) uptake pathways in snails did not inhibit Ni uptake, suggesting that the uptake of Ni does not occur via Ca(2+) uptake pathways. As with Cu and Pb, the exact mechanism for the significant disruption in Ca(2+) homeostasis and reduction in juvenile snail growth remains unknown.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Magnesio, powder, ≥99%
Sigma-Aldrich
Raney®-Nickel, W.R. Grace and Co. Raney® 2800, slurry, in H2O, active catalyst
Sigma-Aldrich
Magnesio, purum, for Grignard reactions, ≥99.5%, turnings
Sigma-Aldrich
Magnesio, turnings, reagent grade, 98%
Sigma-Aldrich
Magnesio, ribbon, ≥99.0% Mg basis
Sigma-Aldrich
Nickel, nanopowder, <100 nm avg. part. size, ≥99% trace metals basis
Sigma-Aldrich
Magnesio, chips, 6-35 mesh, 99.98% trace metals basis
Sigma-Aldrich
Nickel, powder, <50 μm, 99.7% trace metals basis
Sigma-Aldrich
Raney®-Nickel, W.R. Grace and Co. Raney® 2400, slurry, in H2O, active catalyst
Sigma-Aldrich
Nickel, powder, <150 μm, 99.99% trace metals basis
Sigma-Aldrich
Nickel, foil, thickness 0.125 mm, ≥99.9%
Sigma-Aldrich
Raney®-Nickel, W.R. Grace and Co. Raney® 4200, slurry, in H2O, active catalyst
Sigma-Aldrich
Magnesio, turnings, 5-25 mm, 99.95% trace metals basis
Sigma-Aldrich
Nickel, wire, diam. 0.25 mm, ≥99.9%
Sigma-Aldrich
Nickel, foil, thickness 0.5 mm, 99.98% trace metals basis
Sigma-Aldrich
Nickel, powder, <1 μm, 99.8% trace metals basis
Sigma-Aldrich
Raney®-Nickel, W.R. Grace and Co. Raney® 3202, slurry, in H2O, active catalyst
Sigma-Aldrich
Magnesio, wire, 127 μm diameter, 99.9% trace metals basis
Sigma-Aldrich
Nickel, foil, thickness 0.25 mm, 99.995% trace metals basis
Sigma-Aldrich
Magnesium preparation, Highly Reactive Rieke® Metal, suspension, 2.5 g in THF
Nickel, pellets, 100g, max. size 10mm, 99.999%
Sigma-Aldrich
Nickel, foil, thickness 0.1 mm, 99.98% trace metals basis
Sigma-Aldrich
Magnesio, dendritic pieces, purified by distillation, 99.998% trace metals basis
Sigma-Aldrich
Nickel, rod, diam. 6.35 mm, ≥99.99% trace metals basis
Sigma-Aldrich
Magnesio, grit, ≥99.0% (KT)
Sigma-Aldrich
Magnesio, 20-230 mesh, reagent grade, 98%
Sigma-Aldrich
Nickel, sputtering target, diam. × thickness 2.00 in. × 0.25 in., 99.95% trace metals basis
Sigma-Aldrich
Magnesio, ReagentPlus®, powder, −325 mesh, 99.5% trace metals basis
Sigma-Aldrich
Nickel, wire, diam. 0.5 mm, ≥99.99% trace metals basis
Nickel, foil, 100x100mm, thickness 1.6mm, 99%