Saltar al contenido
MilliporeSigma
  • Development and application of a validated stability-indicating high-performance liquid chromatographic method using photodiode array detection for simultaneous determination of granisetron, methylparaben, propylparaben, sodium benzoate, and their main degradation products in oral pharmaceutical preparations.

Development and application of a validated stability-indicating high-performance liquid chromatographic method using photodiode array detection for simultaneous determination of granisetron, methylparaben, propylparaben, sodium benzoate, and their main degradation products in oral pharmaceutical preparations.

Journal of AOAC International (2011-12-15)
Ismail Hewala, Hamed El-Fatatry, Ehab Emam, Mokhtar Mabrouk
RESUMEN

A simple, rapid, and sensitive RP-HPLC method using photodiode array detection was developed and validated for the simultaneous determination of granisetron hydrochloride, 1-methyl-1H-indazole-3-carboxylic acid (the main degradation product of granisetron), sodium benzoate, methylparaben, propylparaben, and 4-hydroxybenzoic acid (the main degradation product of parabens) in granisetron oral drops and solutions. The separation of the compounds was achieved within 8 min on a SymmetryShield RP18 column (100 x 4.6 mm id, 3.5 microm particle size) using the mobile phase acetonitrile--0.05 M KH2PO4 buffered to pH 3 using H3PO4 (3+7, v/v). The photodiode array detector was used to test the purity of the peaks, and the chromatograms were extracted at 240 nm. The method was validated, and validation acceptance criteria were met in all cases. The robust method was successfully applied to the determination of granisetron and preservatives, as well as their degradation products in different batches of granisetron oral drops and solutions. The method proved to be sensitive for determination down to 0.04% (w/w) of granisetron degradation product relative to granisetron and 0.03% (w/w) 4-hydroxybenzoic acid relative to total parabens.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Supelco
Metil 4-hidroxibenzoato, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Propylparaben, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Benzoato de sodio, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Metil 4-hidroxibenzoato, ReagentPlus®, ≥99.0%, crystalline
Supelco
Methyl Paraben, PESTANAL®, analytical standard
Sigma-Aldrich
Benzoato de sodio, ReagentPlus®, 99%
Sigma-Aldrich
Propyl 4-hydroxybenzoate, ≥99%
Sigma-Aldrich
Metil 4-hidroxibenzoato, BioReagent, suitable for insect cell culture
Sigma-Aldrich
Metil 4-hidroxibenzoato, ≥99%, FCC
Sigma-Aldrich
Benzoato de sodio, puriss., meets analytical specification of Ph. Eur., BP, FCC, E211, 99.0-100.5% (calc. to the dried substance), powder
Sigma-Aldrich
Benzoato de sodio, BioXtra, ≥99.5%
Metil 4-hidroxibenzoato, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Benzoato de sodio, purum p.a., ≥99.0% (NT)
Sigma-Aldrich
Propyl 4-hydroxybenzoate, BioXtra
Supelco
Granisetron hydrochloride, Pharmaceutical Secondary Standard; Certified Reference Material
Propyl parahydroxybenzoate, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Metil 4-hidroxibenzoato, tested according to Ph. Eur.
Sigma-Aldrich
Metil 4-hidroxibenzoato, BioXtra, ≥99.0% (titration)
Sigma-Aldrich
Propyl 4-hydroxybenzoate, tested according to Ph. Eur.
Sigma-Aldrich
Metil 4-hidroxibenzoato, analytical standard
Sigma-Aldrich
Benzoato de sodio, SAJ special grade, ≥99.0%
Sigma-Aldrich
Metil 4-hidroxibenzoato, SAJ first grade, ≥98.0%