跳轉至內容
Merck
全部照片(1)

重要文件

34918

Sigma-Aldrich

2,2,4-三甲基戊烷

≥99.5% (GC)

同義詞:

异辛烷

登入查看組織和合約定價


About This Item

線性公式:
(CH3)2CHCH2C(CH3)3
CAS號碼:
分子量::
114.23
Beilstein:
1696876
EC號碼:
MDL號碼:
分類程式碼代碼:
12190000

蒸汽密度

3.9 (vs air)

蒸汽壓力

41 mmHg ( 21 °C)

化驗

≥99.5% (GC)

自燃溫度

745 °F

expl. lim.

6 %

技術

UV/Vis spectroscopy: suitable

雜質

≤0.0005% non-volatile matter
≤0.001% free acid (as CH3COOH)
≤0.005% water (Karl Fischer)
≤1 ppb fluorescence (quinine) at 254 nm
≤1 ppb fluorescence (quinine) at 365 nm

透射率

210 nm, ≥50%
220 nm, ≥80%
230 nm, ≥90%
245 nm, ≥97%
255 nm, ≥99%

折射率

n20/D 1.391 (lit.)

bp

98-99 °C (lit.)

mp

−107 °C (lit.)

密度

0.692 g/mL at 25 °C (lit.)

適合性

passes test for IR spectroscopy
passes test for suitability for UV spectroscopy

SMILES 字串

CC(C)CC(C)(C)C

InChI

1S/C8H18/c1-7(2)6-8(3,4)5/h7H,6H2,1-5H3

InChI 密鑰

NHTMVDHEPJAVLT-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

其他說明

Pertains only in Germany: unversteuert

訊號詞

Danger

危險分類

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

標靶器官

Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

10.4 °F - closed cup

閃點(°C)

-12 °C - closed cup

個人防護裝備

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Luyan Xue et al.
Colloids and surfaces. B, Biointerfaces, 105, 81-86 (2013-01-29)
Choline acetate is an ionic liquid composed of a kosmotropic anion and a chaotropic cation. According to Hofmeister series, a kosmotropic anion and/or a chaotropic cation could stabilize an enzyme, thereby facilitating the retention of the catalytic activity of the
Jonas Andersson et al.
Physics in medicine and biology, 56(2), 299-314 (2010-12-17)
A method to correct for the general recombination losses for liquid ionization chambers in continuous beams has been developed. The proposed method has been derived from Greening's theory for continuous beams and is based on measuring the signal from a
Swarna Bansal et al.
Journal of hazardous materials, 190(1-3), 45-50 (2011-04-05)
Separation of secondary emulsions of dispersed droplet size less than 10 μm, by means of fibrous medium is a very complex but important process. The study investigates the influence of thin fibrous filter properties, i.e. surface energy, pore size and
Yufeng Zhang et al.
Journal of chromatography. A, 1252, 67-73 (2012-07-10)
In this study, a polyethylene Pasteur pipette-based ultrasound-assisted emulsification microextraction (USAEME) applying low-density organic solvent was successfully developed for the extraction of trace levels of organochlorine pesticides (OCPs) in water samples and followed by gas chromatography-mass spectrometry (GC-MS) analysis. In
Kyung Min Park et al.
Food chemistry, 138(2-3), 733-738 (2013-02-16)
In this study, we investigated the possibility of reversed micelles, widely used as an enzyme reactor for lipases, for the determination of lipoxygenase activity. Although it is rapid and simple, reversed micelles have some limitations, such as interference by UV-absorbing

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務