Skip to Content
Merck
  • Myricetin prevents titanium particle-induced osteolysis in vivo and inhibits RANKL-induced osteoclastogenesis in vitro.

Myricetin prevents titanium particle-induced osteolysis in vivo and inhibits RANKL-induced osteoclastogenesis in vitro.

Biochemical pharmacology (2014-12-03)
Chuanlong Wu, Wengang Wang, Bo Tian, Xuqiang Liu, Xinhua Qu, Zanjing Zhai, Haowei Li, Fengxiang Liu, Qiming Fan, Tingting Tang, An Qin, Zhenan Zhu
ABSTRACT

Titanium (Ti) particle-induced periprosthetic osteolysis and subsequent aseptic loosening are a primary reason for total hip arthroplasty failure. The aim of this study was to assess the effect of myricetin on Ti particle-induced osteolysis and osteoclastogenesis. We demonstrated that myricetin, a natural plant extract, exerts potent inhibitory effects on Ti particle-induced osteolysis in a mouse calvarial model. Further histological analysis indicated that the inhibition of osteoclast formation and function, and the secretion of inflammatory factors, are key targets for therapeutic agents in the treatment of wear particle-induced osteolysis. In vitro, we found that myricetin suppressed receptor activator of nuclear factor-κB ligand (RANKL)-mediated osteoclast differentiation, bone resorption, and F-actin ring formation in a dose-dependent manner. Moreover, myricetin significantly reduced the expression of osteoclast-specific markers in mouse bone marrow-derived macrophages, including tartrate-resistant acid phosphatase (TRAP), cathepsin K, the calcitonin receptor, V-ATPase d2, c-fos, and nuclear factor of activated T cells (NFAT) c1. Further investigation revealed that myricetin inhibited osteoclastogenesis through the suppression of the nuclear factor-κB (NF-κB) signaling pathway and mitogen-activated protein kinase (MAPK) pathways involving extracellular signal-regulated kinase 1/2 (ERK1/2), p38, and c-Jun N-terminal kinase 1/2 (JNK1/2). While, the inhibition of TNF-α and IL-1β secretion was another reason for the suppressive effect of myricetin on Ti particle-induced osteolysis. Collectively, these findings suggest that myricetin is a potential natural agent for the treatment of periprosthetic osteolysis and other osteoclast-related osteolytic diseases.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium chloride solution, 0.85%
Sigma-Aldrich
Titanium, foil, thickness 2.0 mm, 99.7% trace metals basis
Supelco
Glycine, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Titanium, 5-10 mm, ≥99.99% trace metals basis (purity exclusive of Na and K content)
Sigma-Aldrich
Titanium, wire, diam. 0.81 mm, 99.7% trace metals basis
Sigma-Aldrich
Sodium chloride, random crystals, optical grade, 99.9% trace metals basis
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl
Sigma-Aldrich
Sodium chloride, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Sigma-Aldrich
Sodium chloride, 99.999% trace metals basis
Supelco
Glycine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
Glycine, analytical standard, for nitrogen determination according to Kjeldahl method
Sigma-Aldrich
Sodium chloride, BioPerformance Certified, ≥99% (titration), suitable for insect cell culture, suitable for plant cell culture
Sigma-Aldrich
Sodium chloride, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
Sodium chloride, tablet
Sigma-Aldrich
Sodium chloride, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Sodium chloride solution, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Sodium chloride, BioXtra, ≥99.5% (AT)
Sigma-Aldrich
Sodium chloride, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
Ser-Phe-Leu-Leu-Arg-Asn-Pro-Asn-Asp-Lys-Tyr-Glu-Pro-Phe, ≥97% (HPLC)
Sigma-Aldrich
Sodium chloride solution, 5 M
Sigma-Aldrich
Sodium chloride solution, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
Titanium, wire, diam. 1.0 mm, 99.99% trace metals basis
Titanium, IRMM®, certified reference material, 0.5 mm wire
Sigma-Aldrich
Sodium chloride solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Sodium chloride, BioUltra, for molecular biology, ≥99.5% (AT)
Sigma-Aldrich
Sodium chloride, tested according to Ph. Eur.
Supelco
Sodium chloride, reference material for titrimetry, certified by BAM, >99.5%
Sigma-Aldrich
Glycine, tested according to Ph. Eur.
Sigma-Aldrich
Titanium, foil, thickness 0.127 mm, 99.7% trace metals basis
Sigma-Aldrich
Titanium, foil, thickness 0.025 mm, 99.98% trace metals basis