跳转至内容
Merck
  • Polar organic chemical integrative samplers for pesticides monitoring: impacts of field exposure conditions.

Polar organic chemical integrative samplers for pesticides monitoring: impacts of field exposure conditions.

The Science of the total environment (2014-05-17)
Sophie Lissalde, Nicolas Mazzella, Patrick Mazellier
摘要

This study focuses on how Polar Organic Chemical Integrative Samplers (POCIS) work in real environmental conditions. A selection of 23 polar pesticides and 8 metabolites were investigated by exposure of triplicates of integrative samplers in two rivers in France for successive 14-day periods. The pesticides and metabolites were trapped not only in Oasis HLB sorbent but also in the polyethersulfone (PES) membrane of the POCIS. The distribution of pesticides depended on the molecular structure. The use of the Performance Reference Compound (PRC) is also discussed here. The impact of some environmental parameters and exposure setup on the transfer of pesticides in POCIS sorbent was studied: river flow rate, biofouling on membranes, sampler holding design and position in the stream. Results show a significant impact of river flow velocity on PRC desorption, especially for values higher than 4 cm·s(-1). Some fouling was observed on the PES membrane which could potentially have an impact on molecule accumulation in the POCIS. Finally, the positioning of the sampler in the river did not have significant effects on pesticide accumulation, when perpendicular exposures were used (sampler positioning in front of the water flow). The POCIS with PRC correction seems to be a suitable tool for estimating time-weighted average (TWA) concentrations, for all the molecules except for one of the nine pesticides analyzed in these two French rivers.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙酸乙酯, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.7%
Sigma-Aldrich
乙酸乙酯, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Supelco
乙酸铵, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.8%
Sigma-Aldrich
乙酸乙酯, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
乙酸铵, for molecular biology, ≥98%
Sigma-Aldrich
乙酸乙酯, puriss., meets analytical specification of Ph. Eur., BP, NF, ≥99.5% (GC)
Sigma-Aldrich
乙酸铵 溶液, for molecular biology, 7.5 M
Sigma-Aldrich
乙酸乙酯, anhydrous, 99.8%
Sigma-Aldrich
乙酸铵, 99.999% trace metals basis
Sigma-Aldrich
乙酸铵, reagent grade, ≥98%
Supelco
毒死蜱, PESTANAL®, analytical standard
Sigma-Aldrich
乙酸乙酯, ≥99%, FCC, FG
Supelco
乙酸乙酯, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
乙酸乙酯, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸乙酯, natural, ≥99%, FCC, FG
Sigma-Aldrich
乙酸铵 溶液, BioUltra, for molecular biology, ~5 M in H2O
Supelco
乙酸乙酯, analytical standard
Sigma-Aldrich
乙酸乙酯, biotech. grade, ≥99.8%
Sigma-Aldrich
乙酸铵, BioXtra, ≥98%
Sigma-Aldrich
乙酸铵, BioUltra, for molecular biology, ≥99.0%
Supelco
灭多威, PESTANAL®, analytical standard
Supelco
甲萘威, PESTANAL®, analytical standard
Supelco
毒死蜱, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
乙酸乙酯, ReagentPlus®, ≥99.8%
Supelco
西玛嗪, PESTANAL®, analytical standard
Sigma-Aldrich
1-萘基-N-甲基氨基甲酸酯, 97%