跳转至内容
Merck
  • Off-resonance surface-enhanced Raman spectroscopy from gold nanorod suspensions as a function of aspect ratio: not what we thought.

Off-resonance surface-enhanced Raman spectroscopy from gold nanorod suspensions as a function of aspect ratio: not what we thought.

ACS nano (2013-02-27)
Sean T Sivapalan, Brent M Devetter, Timothy K Yang, Thomas van Dijk, Matthew V Schulmerich, P Scott Carney, Rohit Bhargava, Catherine J Murphy
摘要

Design of nanoparticles for surface-enhanced Raman scattering (SERS) within suspensions is more involved than simply maximizing the local field enhancement. The enhancement at the nanoparticle surface and the extinction of both the incident and scattered light during propagation act in concert to determine the observed signal intensity. Here we explore these critical aspects of signal generation and propagation through experiment and theory. We synthesized gold nanorods of six different aspect ratios in order to obtain longitudinal surface plasmon resonances that incrementally spanned 600-800 nm. The Raman reporter molecule methylene blue was trap-coated near the surface of each nanorod sample, generating SERS spectra, which were used to compare Raman signals. The average number of reporter molecules per nanorod was quantified against known standards using electrospray ionization liquid chromatography mass spectrometry. The magnitude of the observed Raman signal is reported for each aspect ratio along with the attenuation due to extinction in suspension. The highest Raman signal was obtained from the nanorod suspension with a plasmon resonance blue-shifted from the laser excitation wavelength. This finding is in contrast to SERS measurements obtained from molecules dried onto the surface of roughened or patterned metal substrates where the maximum observed signal is near or red-shifted from the laser excitation wavelength. We explain these results as a competition between SERS enhancement and extinction, at the excitation and scattered wavelengths, on propagation through the sample.

材料
货号
品牌
产品描述

Sigma-Aldrich
聚丙烯酸, average Mv ~450,000
Sigma-Aldrich
聚丙烯酸
Sigma-Aldrich
亚甲蓝 溶液, for microscopy, concentrate according to Ehrlich, concentrated, aqueous solution
Sigma-Aldrich
聚丙烯酸 溶液, average Mw ~250,000, 35 wt. % in H2O
Sigma-Aldrich
聚丙烯酸 溶液, average Mw ~100,000, 35 wt. % in H2O
Sigma-Aldrich
聚丙烯酸钠, average Mw ~5,100 by GPC, powder
Sigma-Aldrich
聚丙烯酸钠, average Mw ~2,100
Sigma-Aldrich
聚丙烯酸, average Mv ~1,250,000
Sigma-Aldrich
聚乙烯(丙烯酸,钠盐) 溶液, average Mw ~8,000, 45 wt. % in H2O
Sigma-Aldrich
聚丙烯酸 溶液, average Mw ~2,000, 50 wt. % in H2O, electronic grade
Sigma-Aldrich
聚乙烯(丙烯酸,钠盐) 溶液, average Mw ~1,200, 45 wt. % in H2O
Sigma-Aldrich
聚丙烯酸, average Mv ~4,000,000
Sigma-Aldrich
聚丙烯酸, average Mv ~3,000,000
Sigma-Aldrich
亚甲蓝 溶液, for microscopy
Sigma-Aldrich
亚甲蓝 溶液, suitable for microbiology
Supelco
聚丙烯酸钠, analytical standard, for GPC, 16,000
Supelco
聚丙烯酸, analytical standard, average Mn 130,000 (Typical)