Skip to Content
Merck
  • The equivalence of diffusive samplers to reference methods for monitoring O3, benzene and NO2 in ambient air.

The equivalence of diffusive samplers to reference methods for monitoring O3, benzene and NO2 in ambient air.

Journal of environmental monitoring : JEM (2008-08-30)
Daniela Buzica, Michel Gerboles, Hervé Plaisance
ABSTRACT

A study of the equivalence to the reference methods of the Radiello samplers for ozone (O(3)) and benzene as well as the membrane-closed Palmes tube (MCPT) for nitrogen dioxide (NO(2)) is presented. These samplers benefit from new model equations capable of estimating their uptake rate. For O(3), the aim here was to demonstrate the equivalence for the reference period of 8 h and 120 microg m(-3), the target value of the 3rd European Daughter Directive. For benzene, the demonstration of equivalence to the annual limit value of 5 microg m(-3) of the 2nd European Daughter Directive was examined. In the case of NO(2), the equivalence to the annual limit value of the 1st European Daughter Directive (40 microg m(-3)) was considered. Results show that the radial sampler for O(3) fails to meet the Data Quality Objective (DQO) for continuous monitoring. However, with an expanded uncertainty of less than 30%, the O(3) diffusive sampler fulfils the DQO for indicative measurements. For benzene, the Radiello sampler exposed for 7 days gave satisfying results showing the ability of the sampler to meet the DQO of the reference method. Nevertheless, the field tests should be complemented by measurements for a wider range of benzene concentrations. In the case of NO(2), all the results of the laboratory and field experiments respected the requirements necessary for the demonstration of equivalence. Overall, these findings thus show that the Radiello sampler and the MCPT are equivalent to the reference methods only for assessment of benzene and NO(2), respectively.

MATERIALS
Product Number
Brand
Product Description

radiello Clips, suspending Radiello triangular support plate, pk of 20
radiello Diffusive Bodies, blue, configured for sampling light sensitive compounds, pk of 20
radiello Empty Storage Tubes, glass (with stopper), volume 2.8 mL, pk of 100
radiello Diffusive Bodies, yellow, configured for reduced sampling rates, pk of 20
radiello BTEX/VOC Starter Kit, Thermal Desorption
radiello BTEX/VOC Starter Kit, CS2 Desorption
radiello On-Field Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello Diffusive Bodies, white, configured for general use, pk of 20
Supelco
radiello Aldehyde Calibration Standard, 50 μg/mL each component in acetonitrile, pkg of 10 mL
radiello On-Field Thermometer, Reader, pk of 1
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
radiello Diffusive Bodies, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello 1,3-Butadiene Starter Kit, Thermal Desorption, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
radiello Hydrogen Sulfide Starter Kit
radiello Anesthetic Gases and Vapor Sampler
radiello Replacement Mounting Strips, for use with Radiello Outdoor Shelter, pk of 100
radiello Outdoor Shelter, pk of 10
radiello Triangular Support Plate, pk of 20
radiello Barcode Labels, pk of 198
radiello Vertical Adapter, threaded for standard use, pk of 20