CCGL53TP1
Charged Durapore® 0.22 µm, Cartridge
cartridge nominal length 30 in. (75 cm), filter diam. 2.7 in. (6.9 cm), Code 5
About This Item
Polecane produkty
Materiały
polypropylene device
polypropylene support
silicone seal
Poziom jakości
sterylność
non-sterile
Kompatybilność ze sterylizacją
autoclavable compatible
steam-in-place compatible
linia produktu
Durapore®
Właściwości
hydrophilic
producent / nazwa handlowa
Durapore®
Parametry
≤30 mL/min air diffusion at 2.1 bar (30 psig) (in water)
0.35 bar max. differential pressure (5 psid) at 135 °C (forward)
0.35 bar max. inlet pressure (5 psi) at 135 °C (forward)
1.7 bar max. differential pressure (25 psid) at 80 °C (forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (forward)
3.5 bar max. differential pressure (50 psid) at 25 °C (reverse)
3.5 bar max. inlet temp. (50 psi) at 25 °C (reverse)
45 L/min flow rate at 400 mbar (ΔP)
5.5 bar max. differential pressure (80 psid) at 25 °C (forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (forward)
metody
sterile filtration: suitable
Długość
30 in.
Szerokość
2.7 in.
długość nominalna kartridża
30 in. (75 cm)
device size
30 in.
śr. filtra
2.7 in. (6.9 cm)
filter filtration area
2.07 m2
zanieczyszczenia
≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
substancje ekstrahujące się grawimetrycznie
≤20 mg/cartridge
macierz
Charged Durapore®
wielkość porów
0.22 μm pore size
punkt pęcherzykowania
≥2760 mbar (40 psig), air with water
kod
Code 5
Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów
Opis ogólny
Cartridge type: Liquid
Opakowanie
Uwaga dotycząca przygotowania
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Komentarz do analizy
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 500 mL
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer to Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Informacje prawne
Not finding the right product?
Try our Narzędzie selektora produktów.
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej