Skip to Content
Merck
  • Simultaneous determination of perfluorinated compounds and their potential precursors in mussel tissue and fish muscle tissue and liver samples by liquid chromatography-electrospray-tandem mass spectrometry.

Simultaneous determination of perfluorinated compounds and their potential precursors in mussel tissue and fish muscle tissue and liver samples by liquid chromatography-electrospray-tandem mass spectrometry.

Journal of chromatography. A (2015-02-25)
I Zabaleta, E Bizkarguenaga, A Prieto, M Ortiz-Zarragoitia, L A Fernández, O Zuloaga
ABSTRACT

An analytical method for the simultaneous determination in fish liver and muscle tissue and mussel samples of 14 perfluorinated compounds (PFCs), including three perfluoroalkylsulfonates (PFSAs), seven perfluorocarboxylic acids (PFCAs), three perfluorophosphonic acids (PFPAs) and perfluorooctanesulfonamide (PFOSA), and 10 potential precursors, including four polyfluoroalkyl phosphates (PAPs), four fluorotelomer saturated acids (FTCAs) and two fluorotelomer unsaturated acids (FTUCAs), was developed in the present work. Different clean-up strategies by means of solid-phase extraction (SPE) using a mix-mode weak anion exchanger (WAX), reverse phase Envi-Carb or a combination of them was optimized and evaluated for the clean-up of focused ultrasonic solid-liquid (FUSLE) extracts before the analysis by liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS). Mix-mode WAX coupled in-line to Envi-Carb was finally selected since it rendered the cleanest extracts and minimum matrix effect. The FUSLE-SPE-LC-MS/MS methodology was validated in terms of recovery, precision and method detection limits (MDLs). Apparent recovery values in the 65-116%, 59-119% and 67-126% range and MDLs in the 0.1-2.7 ng/g, 0.1-3.8 ng/g and 0.2-3.1ng/g range were obtained for liver, mussel and fish muscle tissue samples, respectively. The method developed was applied to the analysis of grey mullet liver (Chelon labrosus) and mussel (Mytilus galloprovincialis) samples from the Basque Coast (North of Spain) and Yellowfin tuna muscle tissue (Thunnus albacares) samples from the Indian Ocean. To the best of our knowledge this is the first method that describes the simultaneous determination of 14 PFCs and 10 potential precursors in fish liver, fish muscle tissue and mussel samples. Besides, this is the first time that 8:2 monosubstituted polyfluorodecyl phosphate (8:2 monoPAP) and 8:2 disubstituted polyfluorodecyl phosphate (8:2 diPAP) were detected in mussel and tuna samples, respectively.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methane-12C, 13C-depleted, 99.99 atom % 12C
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Supelco
Supel QuE, PSA/ENVI-Carb Tube 1, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Supelco
Supel QuE, PSA/C18/ENVI-Carb Tube, pk of 50, AOAC® 2007.01, centrifuge tube volume 15 mL , Shaker Compatible
Supelco
Supel QuE, PSA/ENVI-Carb Tube 2, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Ammonium hydroxide solution, BioUltra, ~1 M NH3 in H2O (T)
USP
Glacial acetic acid, United States Pharmacopeia (USP) Reference Standard
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, AR, ≥99.5%
Sigma-Aldrich
Ammonium hydroxide solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Acetonitrile, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Ammonium hydroxide solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Ammonium acetate solution, Molecular Biology, 7.5 M
Sigma-Aldrich
Acetic acid, glacial, ACS reagent, ≥99.7%
Supelco
Acetic acid, analytical standard
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Acetic acid, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
Acetic acid, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Acetic acid, glacial, ReagentPlus®, ≥99%