Saltar al contenido
Merck

59353-U21

Supelco

Discovery® C8 (5 µm) HPLC Columns

L × I.D. 15 cm × 2.1 mm, HPLC Column

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41115700
eCl@ss:
32110501
NACRES:
SB.52

product name

Columna para HPLC Discovery® C8, 5 μm particle size, L × I.D. 15 cm × 2.1 mm

material

stainless steel column

agency

suitable for USP L7

product line

Discovery®

feature

endcapped

manufacturer/tradename

Discovery®

packaging

1 ea of

extent of labeling

7.5% Carbon loading

parameter

≤70 °C temp. range
400 bar pressure (5801 psi)

technique(s)

HPLC: suitable
LC/MS: suitable

L × I.D.

15 cm × 2.1 mm

surface area

200 m2/g

surface coverage

3.4 μmol/m2

impurities

<10 ppm metals

matrix

silica gel, high purity, spherical base material
fully porous particle

matrix active group

C8 (octyl) phase

particle size

5 μm

pore size

180 Å

operating pH range

2-8

application(s)

food and beverages

separation technique

reversed phase

¿Está buscando productos similares? Visita Guía de comparación de productos

Features and Benefits

Características de la Discovery® C8:
• Selectividad y retención clásica C18
• Excelente forma del pico
• Estable, separaciones CL/EM (LC/MS) sin sangrado
• Similar selectividad que la C18, con menor retención hidrófoba.

Legal Information

Discovery is a registered trademark of Merck KGaA, Darmstadt, Germany

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Rahul Palchaudhuri et al.
Cell reports, 13(9), 2027-2036 (2015-12-15)
Apoptosis is generally believed to be a process that requires several hours, in contrast to non-programmed forms of cell death that can occur in minutes. Our findings challenge the time-consuming nature of apoptosis as we describe the discovery and characterization
Laurence Conraux et al.
PloS one, 8(11), e79733-e79733 (2013-11-14)
The diagnostic of Amyotrophic lateral sclerosis (ALS) remains based on clinical and neurophysiological observations. The actual delay between the onset of the symptoms and diagnosis is about 1 year, preventing early inclusion of patients into clinical trials and early care
Bo-Rui Kang et al.
Bioorganic & medicinal chemistry letters, 25(24), 5808-5812 (2015-11-08)
2-Benzylisoquinolin-1(2H)-ones has been proposed as vasodilative agents on the basis of scaffold hopping. In the present study, a series of 2-benzylisoquinolin-1(2H)-ones were synthesized. Their vasodilative effects were evaluated by wire myograph on isolated rat mesenteric arterial ring induced contraction with
M Q Zhang et al.
Die Pharmazie, 46(10), 687-700 (1991-10-01)
The rapid growth in the quinolone research changed the whole face of the previous SAR concepts. So far structural modifications at all positions of the quinolone nucleus except the 4-oxo group have successfully lead to the discovery of potent antimicrobial
G L Bundy et al.
The Journal of biological chemistry, 261(2), 747-751 (1986-01-15)
The gorgonian coral Pseudoplexaura porosa contains a lipoxygenase capable of converting exogenous arachidonic acid into (8R)-8-hydroperoxy-5,9,11,14-eicosatetraenoic acid. The (8R)- (or 8-L-) configuration in this product, opposite to that observed in previously reported 8-lipoxygenase products, was determined unambiguously by comparison of

Contenido relacionado

Discovery C18 and C8 HPLC Columns products offered

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico