Lights and shadows of the actual European guidelines on bioanalytical method validation: the case of raltegravir.

Therapeutic drug monitoring (2014-04-18)
Sara Baldelli, Dario Cattaneo, Serena Fucile, Emilio Clementi
RESUMEN

Recently, the European Medicines Agency (EMA) has released new guidelines on the validation of bioanalytical methods. In this work, we compared the analytical performance of 2 high-performance liquid chromatography with tandem mass spectrometry methods designed for the quantification of the antiretroviral drug raltegravir (RAL) that fully accomplish the criteria according to the new EMA guidelines. The first method was developed with the goal of separating RAL from its main metabolite, whereas in the second method, we deliberately did not discriminate the parent drug from its metabolite. After validation, both methods were used for the quantification of plasma samples from HIV-infected patients on RAL-based maintenance antiretroviral therapy. Incurred reanalysis of samples obtained from patients receiving RAL as therapy evidenced optimal performance for both methods. Similarly, the comparison of both methods performed by the Deming test showed that they correlate significantly with each other (Pearson coefficient of regression 0.97, P < 0.0001) with no significant deviation from linearity according to the Cusum test. The Bland-Altman test, however, showed a mean difference between the 2 methods of 54.1% (limits of agreements of ±1.96 SD ranged from -163.3% to +271.5%). Such differences were significantly affected by interindividual variations in the production of RAL metabolites. We conclude that the recently released EMA guidelines on bioanalytical method validation present some limitations related to the process of method development. To have confidence in the drug-concentration measurements, laboratories must demonstrate their performance through the participation in international proficiency testing schemes that must include patient samples.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanol, Absolute - Acetone free
Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Supelco
Ammonium acetate, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Metanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
USP
Metanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Potassium, chunks (in mineral oil), 98% trace metals basis
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Potassium hydride, 30 wt % dispersion in mineral oil
Sigma-Aldrich
Metanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Supelco
Metanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
Metanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Supelco
Metanol, analytical standard
Sigma-Aldrich
Potassium hydride, in paraffin
Sigma-Aldrich
Metanol, SAJ special grade