Saltar al contenido
Merck
  • Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. II: Analysis of biological samples.

Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. II: Analysis of biological samples.

Analytica chimica acta (2014-12-04)
Lucie Nováková, Marco Rentsch, Alexandre Grand-Guillaume Perrenoud, Raul Nicoli, Martial Saugy, Jean-Luc Veuthey, Davy Guillarme
RESUMEN

The potential and applicability of UHPSFC-MS/MS for anti-doping screening in urine samples were tested for the first time. For this purpose, a group of 110 doping agents with diverse physicochemical properties was analyzed using two separation techniques, namely UHPLC-MS/MS and UHPSFC-MS/MS in both ESI+ and ESI- modes. The two approaches were compared in terms of selectivity, sensitivity, linearity and matrix effects. As expected, very diverse retentions and selectivities were obtained in UHPLC and UHPSFC, proving a good complementarity of these analytical strategies. In both conditions, acceptable peak shapes and MS detection capabilities were obtained within 7 min analysis time, enabling the application of these two methods for screening purposes. Method sensitivity was found comparable for 46% of tested compounds, while higher sensitivity was observed for 21% of tested compounds in UHPLC-MS/MS and for 32% in UHPSFC-MS/MS. The latter demonstrated a lower susceptibility to matrix effects, which were mostly observed as signal suppression. In the case of UHPLC-MS/MS, more serious matrix effects were observed, leading typically to signal enhancement and the matrix effect was also concentration dependent, i.e., more significant matrix effects occurred at the lowest concentrations.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Tetrahidrofuran, inhibitor-free, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Tetrahidrofuran, contains 250 ppm BHT as inhibitor, ACS reagent, ≥99.0%
Sigma-Aldrich
Formato de amonio, reagent grade, 97%
Sigma-Aldrich
Tetrahidrofuran, anhydrous, ≥99.9%, inhibitor-free
Sigma-Aldrich
Formato de amonio, ≥99.995% trace metals basis
Sigma-Aldrich
Tetrahidrofuran, anhydrous, contains 250 ppm BHT as inhibitor, ≥99.9%
Supelco
Formato de amonio, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Tetrahidrofuran, ReagentPlus®, ≥99.0%, contains 250 ppm BHT as inhibitor
Sigma-Aldrich
Tetrahidrofuran, contains 250 ppm BHT as inhibitor, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99.9%
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Tetrahidrofuran, ACS reagent, ≥99.0%, contains 250 ppm BHT as inhibitor
Sigma-Aldrich
Furosemide
Sigma-Aldrich
Argon, ≥99.998%
Sigma-Aldrich
Acetazolamide, ≥99%, powder
Sigma-Aldrich
Tetrahidrofuran, suitable for HPLC, contains no stabilizer
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Bumetanide, ≥98%
Sigma-Aldrich
Tetrahidrofuran, SAJ first grade, ≥99.0%
Sigma-Aldrich
Formato de amonio, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Supelco
Tetrahidrofuran, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Tetrahidrofuran, suitable for HPLC, ≥99.9%, inhibitor-free
Sigma-Aldrich
Ethacrynic acid, ≥97% (HPLC)
Supelco
Furosemide, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Tetrahidrofuran, JIS special grade, ≥99.5%
USP
Furosemide, United States Pharmacopeia (USP) Reference Standard
Supelco
Tetrahidrofuran, analytical standard
Supelco
Tetrahidrofuran, Selectophore, ≥99.5%
USP
Acetazolamide, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Metolazone, ≥98% (HPLC), solid
USP
Indapamide, United States Pharmacopeia (USP) Reference Standard