Skip to Content
Merck
  • Hollow fiber based liquid-liquid-liquid microextraction combined with sweeping micellar electrokinetic chromatography for the sensitive determination of second-generation antidepressants in human fluids.

Hollow fiber based liquid-liquid-liquid microextraction combined with sweeping micellar electrokinetic chromatography for the sensitive determination of second-generation antidepressants in human fluids.

The Analyst (2015-01-27)
Xiaoqing Zhou, Man He, Beibei Chen, Bin Hu
ABSTRACT

An effective dual preconcentration method involving off-line hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) and on-line sweeping micellar electrokinetic chromatography (sweeping-MEKC) was proposed for the determination of five second-generation antidepressants, including fluoxetine, sertraline, paroxetine, fluvoxamine and citalopram. In HF-LLLME, the analytes were extracted from the sample solution into phenetole impregnated in the pores of the hollow fiber and then back-extracted into 10 μL 0.1 mol L(-1) HAc inside the hollow fiber. Then, the acceptor phase was spiked with 2.8 μL isopropanol (IPA) and introduced into CE for sweeping. In the sweeping-MEKC process, five target analytes were separated in less than 15 min with a background electrolyte consisting of 76% (v/v) 50 mmol L(-1) citric acid (pH 2.2) containing 100 mmol L(-1) sodium dodecyl sulfate (SDS) and 24% (v/v) IPA. The hydrodynamic injection was performed at 50 mbar for 140 s. Under optimized conditions, the limits of detection were in the range of 0.40-1.55 μg L(-1) with enrichment factors of 1897- to 5952-fold for target analytes, with a dynamic linear range of 0.6/5.0-200 μg L(-1). The developed method demonstrated excellent clean-up ability and high enrichment factors and was successfully applied to the analysis of target analytes in human urine and plasma samples.

MATERIALS
Product Number
Brand
Product Description

Supelco
Citric acid, Anhydrous, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
2-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
5α-Androstan-17β-ol-3-one, VETRANAL®, analytical standard
Sigma-Aldrich
Ethoxybenzene, 99%
Sigma-Aldrich
Citric acid, ACS reagent, ≥99.5%
Supelco
2-Propanol, analytical standard
Sigma-Aldrich
2-Propanol, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Sodium phosphate dibasic, BioUltra, for molecular biology, ≥99.5% (T)
Supelco
Toluene, analytical standard
Sigma-Aldrich
Sodium phosphate dibasic, purum p.a., anhydrous, ≥98.0% (T)
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, purum, ≥99.0% (TLC)
Sigma-Aldrich
2-Hydroxybutyric acid sodium salt, 97%
Sigma-Aldrich
Citric acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Sodium phosphate dibasic, BioXtra, ≥99.0%
Sigma-Aldrich
Sodium phosphate dibasic, BioReagent, suitable for cell culture, suitable for insect cell culture, ≥99.0%
Sigma-Aldrich
Sodium phosphate dibasic, ReagentPlus®, ≥99.0%
Sigma-Aldrich
β-D-Allose, rare aldohexose sugar
Sigma-Aldrich
Sodium phosphate dibasic, for molecular biology, ≥98.5% (titration)
Sigma-Aldrich
Citric acid, 99%
Sigma-Aldrich
2-Propanol, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%, poly coated bottles
Sigma-Aldrich
2-Propanol, for molecular biology, BioReagent, ≥99.5%
Citric acid, anhydrous, European Pharmacopoeia (EP) Reference Standard
Supelco
Toluene, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2-Propanol, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
2-Propanol, puriss. p.a., ACS reagent, ≥99.8% (GC)
Sigma-Aldrich
Citric acid, anhydrous, suitable for cell culture, suitable for plant cell culture
Sigma-Aldrich
Sodium phosphate dibasic, 99.95% trace metals basis
USP
Citric acid, United States Pharmacopeia (USP) Reference Standard