Skip to Content
Merck
  • Selective extraction and analysis of catecholamines in rat blood microdialysate by polymeric ionic liquid-diphenylboric acid-packed capillary column and fast separation in high-performance liquid chromatography-electrochemical detector.

Selective extraction and analysis of catecholamines in rat blood microdialysate by polymeric ionic liquid-diphenylboric acid-packed capillary column and fast separation in high-performance liquid chromatography-electrochemical detector.

Journal of chromatography. A (2015-07-25)
Xinguang Zhou, Anwei Zhu, Guoyue Shi
ABSTRACT

Concentration of blood catecholamines (CAs) is linked to a host of cardiovascular diseases, including hypertension and stenocardia. The matrix interferences and low concentration require tedious sample pretreatment methods before quantitative analysis by the gold standard method of high-performance liquid chromatography-electrochemical detector (HPLC-ECD). Solid phase extraction (SPE) has been widely used as the pretreatment technique. Here, a facile polymeric ionic liquid (PIL)-diphenylboric acid (DPBA)-packed capillary column was prepared to selectively extract dopamine (DA), noradrenaline (NE) and epinephrine (E) prior to their quantitative analysis by a fast separation in HPLC-ECD method, while microdialysis sampling method was applied to get the analysis sample. Parameters that influenced desorption efficiency, such as pH, salt concentration, acetonitrile content and wash time, were examined and optimized. The proposed method, combining microdialysis sampling technique, SPE and HPLC-ECD system, was successfully applied to detect CAs in rat blood microdialysate with high sensitivity and selectivity in small sample volumes (5-40μl) and a short analysis time (8min), yielding good reproducibility (RSD 6.5-7.7%) and spiked recovery (91-104.4%).

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
Divinylbenzene, technical grade, 80%
Sigma-Aldrich
Isopropyl alcohol, ≥99.7%, FCC, FG
Sigma-Aldrich
Divinylbenzene, technical grade, 55%
Sigma-Aldrich
1-Chloro-3-phenylpropane, 99%
Sigma-Aldrich
DL-4-Hydroxy-3-methoxymandelic acid, ≥98% (HPLC), powder
Sigma-Aldrich
Homovanillic acid, Fluorimetric reagent
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
2-Propanol, anhydrous, 99.5%
Sigma-Aldrich
8-Octanoyloxypyrene-1,3,6-trisulfonic acid trisodium salt, suitable for fluorescence, ≥90% (HPCE)
Sigma-Aldrich
Dimethyl sulfoxide, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Dimethyl sulfoxide, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
2-Propanol, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Dimethyl sulfoxide, anhydrous, ≥99.9%
Sigma-Aldrich
Dimethyl sulfoxide, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
Dimethyl sulfoxide, PCR Reagent
Sigma-Aldrich
2-Propanol, for molecular biology, BioReagent, ≥99.5%
Sigma-Aldrich
Dimethyl sulfoxide, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
Dimethyl sulfoxide, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
2-Propanol, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%, poly coated bottles
Sigma-Aldrich
Dimethyl sulfoxide, for molecular biology
Sigma-Aldrich
Methanol solution, (Methanol:Dimethyl sulfoxide 1:1 (v/v))
Sigma-Aldrich
2-Propanol, electronic grade, 99.999% trace metals basis