Saltar al contenido
Merck

GC Analysis of Volatiles in Drywall on SPB®-HAP after Collection/Desorption using Carbotrap® 300 Tube

GC Analysis of Volatiles in Drywall on SPB®-HAP after Collection/Desorption using Carbotrap® 300 Tube suitable for GC, application for air monitoring

Materiales

related product

Referencia del producto
Descripción
Precios

ATIS Adsorbent Tube Injector System 110V

ATIS Adsorbent Tube Injector System 220V

ATIS Purge and Trap/Humidifier Module

Carbotrap® 300

glass TD tube, fritted, O.D. × L 1/4 in. × 3 1/2 in., unconditioned, pkg of 10 ea

CONDITIONS

sample/matrix

1g 1/4 in drywall

thermal desorption tube

Carbotrap® 300 Glass-Fritted Thermal Desorption Tube, 1/4 in O.D. x 3.5 in L (30141-U)

dry purge

60 min

desorption process

350 °C with 10 min hold

transfer line/valve temp.

180 °C

column

SPB-HAP, 60 m x 0.32 mm I.D., 4 μm (25020-U)

oven

40 °C (3 min), 12 °C/min to 200 °C (20 min)

detector

MSD

MSD interface

210 °C

carrier gas

helium

Descripción

Analysis Note

Qualitative volatile headspace outgassing of drywall using the ATIS with analysis by thermal desorption

Legal Information

Carbotrap is a registered trademark of Merck KGaA, Darmstadt, Germany
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany