Saltar al contenido
Merck

Multiresidue method using SPME for the determination of various pesticides with different volatility in confined atmospheres.

Analytical and bioanalytical chemistry (2004-04-16)
Federico Ferrari, Astrid Sanusi, Maurice Millet, Michel Montury
RESUMEN

An analytical method is described for assessing the vapour concentration of 11 pesticides (bioallethrin, chlorpyriphos methyl, folpet, malathion, procymidone, quintozene, chlorothalonil, fonofos, penconazole and trimethacarb) in confined atmospheres (e.g. a greenhouse after pesticide application). This study is a successful extension of a method previously developed by the authors for dichlorvos to much less volatile pesticides. Sampling was performed by using polydimethylsiloxane-solid phase micro-extraction (PDMS-SPME) fibres immersed in a 250-mL sampling flask through which air samples were dynamically pumped from the analysed atmosphere. After a 40-min sampling duration, samples were analysed by GC/MS. Calibration was performed from a vapour-saturated air sample. The linearity of the observed signal versus pesticide concentration in the vapour phase was proved from spiked liquid samples whose headspace concentrations were measured by using the proposed method. This procedure gave calibration curves with regression coefficients ( R(2)) greater than 0.98, and the repeatability of these measurements was found with RSDs of 1.9-7.6%. As a field application test, this analysis procedure was used for the determination of gaseous procymidone concentrations as a function of time in the atmosphere of an experimental 8-m(2) and 20-m(3) greenhouse. The pesticide was sprayed according to real cultivation conditions, and measurements were made for 80 h after application (8 measurements). The observed concentrations found ranged from 200 to 500 micro g m(-3), thus indicating the level of contamination of the air breathed by people in such working conditions.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, StableFlex
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, for use with manual holder
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
Filtro SPME Polidimetilsiloxano (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Kit de surtido de fibra SPME StableFlex, for use with manual holder
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Kit de surtido de fibra SPME StableFlex, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
SPME fiber assortment kit 4, for use with manual holder, size 24 ga
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga