Saltar al contenido
Merck
  • LC-MS/MS simultaneous quantitation of 2-hydroxyethylated, oxidative, and unmodified DNA nucleosides in DNA isolated from tissues of mice after exposure to ethylene oxide.

LC-MS/MS simultaneous quantitation of 2-hydroxyethylated, oxidative, and unmodified DNA nucleosides in DNA isolated from tissues of mice after exposure to ethylene oxide.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-12-23)
Fagen Zhang, Michael J Bartels, Matthew J LeBaron, Melissa R Schisler, Yo-Chan Jeong, B Bhaskar Gollapudi, Nigel P Moore
RESUMEN

2-Hydroxyethylated and oxidative DNA nucleosides (DNA adduct biomarkers), such as O6-(2-hydroxyethyl)-2'-deoxyguanosine (O6HEdG), N6-(2-hydroxyethyl)-2'-deoxyadenosine (N6HEdA), 1-(2-hydroxyethyl)-2'-deoxyadenosine (N1HEdA), and 8-hydroxy-2'-deoxyguanosine (8-OHdG), N2,3-etheno-2'-deoxyguanosine (N2,3-ethenodG), α-methyl-γ-hydroxy-1,N2-propano-2'-deoxyguanosine (CrotondG), are important proposed biomarkers for exploring the genotoxicity mechanism of ethylene oxide (EO) in vivo. A liquid chromatography-tandem mass spectrometric method was developed for the simultaneous determination of O6HEdG, N6HEdA, N1HEdA, 8-OHdG, CrotondG, and N2,3-ethenodG together with regular 2'-deoxyguanosine (dG), and 2'-deoxyadenosine (dA) nucleosides in the DNA extracted from mouse lung tissues for the assessment of exposure to EO after inhalation. The lower limits of quantitation for 8-OHdG, CrotondG, N2,3-EthenodG, O6HEdG, N1HEdA, N6HEdA, dG, and dA were 0.025, 0.00125, 0.025, 0.00125, 0.025, 0.01, 2342, and 2500ng/mL, respectively. The linearity of the calibration curves for all analytes were >0.989. The intra-day assay precision relative standard deviation (RSD) values for quality control (QC) samples for all analytes were ≤13.5% with accuracy values ranging from 86.5% to 111%. The inter-day assay precision (RSD) values for all analytes were ≤18.8% with accuracy values ranging from 87.9% to 119%. This method was used for simultaneous determination of the levels of 8-OHdG, CrotondG, N2,3-EthenodG, O6HEdG, dG, N1HEdA, N6HEdA, and dA in DNA enzymatic hydrolysates from DNA extracted from mouse lung after 12 weeks' inhalation exposure to EO at atmospheric concentrations of 0, 100, and 200ppm. Overall, N2,3-ethenodG was not detected in any samples. 8-OHdG, CrotondG, dG, and dA were all quantifiable in all samples. O6HEdG, N1HEdA, and N6HEdA were quantifiable in most samples and the ratio of the corresponding adduct versus their corresponding DNA base (dG or dA) [×10 (e6)] was increased as the EO exposure concentration increased.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Ácido acético, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Ácido acético, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Ácido acético, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Ácido acético solution, suitable for HPLC
Sigma-Aldrich
Metanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Ácido acético, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Ácido acético, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Metanol, Absolute - Acetone free
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Sigma-Aldrich
Acetonitrilo, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
USP
Metanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Ácido acético, for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Acetonitrilo, biotech. grade, ≥99.93%