Saltar al contenido
Merck

A membrane bioreactor for the simultaneous treatment of acetone, toluene, limonene and hexane at trace level concentrations.

Water research (2013-03-19)
R Lebrero, D Volckaert, R Pérez, R Muñoz, H Van Langenhove
RESUMEN

The performance of a flat-membrane biofilm reactor (MBR) for the removal of acetone, toluene, limonene and hexane at concentrations ranging from 1.3 to 3.2 mg m(-3) was investigated at different gas residence times (GRT): 60, 30, 15 and 7 s. A preliminary abiotic test was conducted to assess the mass transport of the selected volatile organic compounds (VOCs) through the membrane. A reduced transport of limonene and hexane was observed with water present over the dense side of the membrane. The presence of a biofilm attached on the dense side of the membrane following bioreactor inoculation significantly increased VOC transport. High acetone and toluene removals (>93%) were recorded in the MBR regardless of the GRT. To remediate the low hexane removal performance (RE < 24%) recorded at the initial stages of the process, a re-inoculation of the membrane with a hexane-degrading consortium embedded in silicon oil was performed. Although hexane removal did not exceed 27%, this re-inoculation increased limonene removals up to 90% at a GRT of 7 s. The absence of inhibition of hexane biodegradation by substrate competition confirmed that hexane removal in the MBR was indeed limited by the mass transfer through the membrane. Despite the low carbon source spectrum and load, the microbiological analysis of the communities present in the MBR showed high species richness (Shannon-Wiener indices of 3.2-3.5) and a high pair-wise similarity (84-97%) between the suspended and the attached biomass.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Acetona, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetona, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetona, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Tolueno, ACS reagent, ≥99.5%
Sigma-Aldrich
Tolueno, suitable for HPLC, 99.9%
Sigma-Aldrich
Hexano, suitable for HPLC, ≥97.0% (GC)
Sigma-Aldrich
Tolueno, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Hexano, ReagentPlus®, ≥99%
Sigma-Aldrich
Hexano, suitable for HPLC, ≥95%
Sigma-Aldrich
Acetona, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
Hexano, Laboratory Reagent, ≥95%
Sigma-Aldrich
Tolueno, anhydrous, 99.8%
Sigma-Aldrich
Hexano, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Hexano, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99% (GC)
Sigma-Aldrich
Acetona, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Tolueno, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.7% (GC)
Sigma-Aldrich
Acetona, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
(R)-(+)-Limonene, 97%
Sigma-Aldrich
Acetona, ACS reagent, ≥99.5%
Sigma-Aldrich
Hexano, anhydrous, 95%
Sigma-Aldrich
Acetona, histological grade, ≥99.5%
Sigma-Aldrich
Tolueno, ACS reagent, ≥99.5%
Sigma-Aldrich
Tolueno, Laboratory Reagent, ≥99.3%
Sigma-Aldrich
(S)-(−)-Limonene, 96%
Supelco
Acetona, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Acetona, analytical standard
Sigma-Aldrich
Acetona, natural, ≥97%
Sigma-Aldrich
Acetona, puriss., meets analytical specification of Ph. Eur., BP, NF, ≥99% (GC)
Supelco
(R)-(+)-Limonene, analytical standard
Supelco
Tolueno, analytical standard